IR 05000123/2011201
| ML112570122 | |
| Person / Time | |
|---|---|
| Site: | University of Missouri-Rolla |
| Issue date: | 09/14/2011 |
| From: | Johnny Eads Research and Test Reactors Branch B |
| To: | Bonzer W Missouri Univ of Science & Technology |
| Morlang, G M, NRR/DPR, 415-4092 | |
| References | |
| IR-11-201 | |
| Download: ML112570122 (12) | |
Text
September 14, 2011
SUBJECT:
MISSOURI UNIVERSITY OF SCIENCE AND TECHNOLOGY - NRC ROUTINE INSPECTION REPORT NO.: 50-123/2011-201
Dear Mr. Bonzer:
On August 15-18, 2011, the U.S. Nuclear Regulatory Commission (NRC, the Commission)
conducted an inspection at your Nuclear Reactor Facility (Inspection Report No.
50-123/2011-201). The enclosed report documents the inspection results, which were discussed on August 18, 2011 with you and members of your staff.
Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, no safety concerns or non-compliances with NRC requirements were identified.
No response to this letter is required.
In accordance with Title 10 of the Code of Federal Regulations 2.390, Public inspections, exemptions, and requests for withholding, a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room) http://www.nrc.gov/reading-rm/adams.html.
If you have any questions concerning this inspection, please contact Mike Morlang at 301-415-4092 or Gary.Morlang@nrc.gov.
Sincerely,
/RA/
Johnny H. Eads, Jr. Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
Docket No.: 50-123 License No.: R-79
Enclosure: NRC Inspection Report No.: 50-123/2011-201 cc w/encl: Please see next page
Missouri University of Science and Technology Docket No.: 50-123
cc:
Dr. Samuel Frimpong, Chair Mining and Nuclear Engineering Department 226 McNutt Hall Missouri University of Science and Technology Rolla, MO 65409-0450
Homeland Security Coordinator Missouri Office of Homeland Security P.O. Box 749 Jefferson City, MO 65102
Planner, Dept of Health and Senior Services Section for Environmental Public Health 912 Wildwood Drive, P.O. Box 570 Jefferson City, MO 65102-0570
Deputy Director for Policy Department of Natural Resources 1101 Riverside Drive Fourth Floor East Jefferson City, MO 65101
A-95 Coordinator Division of Planning Office of Administration P.O. Box 809 State Capitol Building Jefferson City, MO 65101
Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
September 14, 2011 Mr. William