IR 05000123/2007201
| ML070430016 | |
| Person / Time | |
|---|---|
| Site: | University of Missouri-Rolla |
| Issue date: | 02/13/2007 |
| From: | Johnny Eads NRC/NRR/ADRA/DPR/PRTB |
| To: | Bonzer W Univ of Missouri - Rolla |
| Voth M, NRR/ADRA/DPR/PRT, 415-1210 | |
| References | |
| IR-07-201 | |
| Download: ML070430016 (20) | |
Text
February 13, 2007
SUBJECT:
NRC INSPECTION REPORT NO.: 50-123/2007-201
Dear Mr. Bonzer:
This letter refers to the inspection conducted on January 16-19, 2007, at your Nuclear Reactor Facility. The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspection.
Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, no safety concerns or noncompliance with NRC requirements were identified.
No response to this letter is required.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room) http://www.nrc.gov/reading-rm/adams.html.
If you have any questions concerning this inspection, please contact Marcus H. Voth in Rockville, MD, at 301-415-1210.
Sincerely,
/RA/
Johnny H. Eads, Branch Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.: 50-123 License No.: R-79 Enclosure: NRC Inspection Report No.: 50-123/2007-201 cc w/enclosure: Please see next page
University of Missouri-Rolla Docket No.: 50-123 cc:
Dr. Mariesa Crow, Dean School of Mines and Metallurgy 305 McNutt Hall University of Missouri-Rolla Rolla, MO 65401 Dan Estel University of Missouri-Rolla Nuclear Reactor Facility 1870 Miner Circle Rolla, MO 65409-0630 Mr. Michael Chapman Missouri Office of Homeland Security P.O. Box 749 Jefferson City, MO 65102 Planner, Dept of Health and Senior Services Section for Environmental Public Health 930 Wildwood Drive, P.O. Box 570 Jefferson City, MO 65102-0570 Deputy Director for Policy Department of Natural Resources 1101 Riverside Drive Fourth Floor East Jefferson City, MO 65101 A-95 Coordinator Division of Planning Office of Administration P.O. Box 809 State Capitol Building Jefferson City, MO 65101 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
Mr. William