IR 05000117/2002003

From kanterella
Jump to navigation Jump to search
Forwards Maint Insp Rept 50-244/95-01 on 950117-0203. Maint Program at Plant Effective & Designed to Provide Very Good Preventive,Predictive & Corrective Maint
ML17263B000
Person / Time
Site: Ginna, 05000117 
Issue date: 03/24/1995
From: Blough A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
Shared Package
ML17263B001 List:
References
NUDOCS 9504040222
Download: ML17263B000 (5)


Text

va.joB.rTY z REGULATORYNIXH93KN9MHES'XGKIBTSUTION SYSTEM ( RIDS )

', ACCESSION NBR:9504040222 DOC.DATE: 95/03/24 NOTARIZED: NO CIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester G

UTH.NAME AUTHOR AFFILIATION OUGH,A.R.

Region 1 (Post 820201)

RECIP.NAME RECIPIENT AFFILIATION MECREDY,R.D.

Rochester Gas

& Electric Corp.

SUBJECT:

Forwards insp rept 50-244/95-01 on 950117-20

& 0130-0203.

Maint program at plant effective

& designed to provide very good preventive, predictive

& corrective maint.

DISTRIBUTION CODE:

IE01D COPIES RECEIVED:LTR ENCL SIZE:

TITLE: General (50 Dkt)-Insp Rept/Notice of Vio ation Response DOCKET 05000244 F

NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

05000244 (

RECIPIENT ID CODE/NAME PD1-3 PD INTERNAL: AEOD/DEIB AEOD/SPD/RRAB DEDRO NRR/DISP/PIPB NRR/DRCH/HHFB OE DIR RGN1 FILE

EXTERNAL: LITCO BRYCE,J H

NRC PDR COPIES LTTR ENCL

1

1

1

1

1

1

1

1

1

1 RECIPIENT ID CODE/NAME JOHNSON,A AEOD/SPD/RAB

~AEGD/'ZT FILE CENTER

NRR DORS/OEAB NUDOCS-ABSTRACT OGC/HDS3 NOAC COPIES LTTR ENCL

1

1

1

1

1

1 1;1

1 D

u E

N VOTE TO ALL"RIDS" RECIPI Eib'TS:.

PLEASE HELP US TO REDUCE iVASTE!COYTACTTHE DOCL'RIED'I COYTROL

~

~

DESK, ROOiil Pl-37 <EXT. 504-2083 ) TO ELIMIYATEYOUR ihAiiIEI'RO.if

SUBJECT:

GINNA MAINTENANCE INSPECTION REPORT 50-244/95-01

Dear Or. Hecredy:

This letter transmits the findings of an inspection of maintenance programs and activities conducted by T. J.

Kenny, J.

H. O'Antonio, and J.

R.

Reyes from January 17 - 20, and January 30 February 3, 1995, at the R.

E. Ginna Nuclear Power Plant.

The inspection was conducted to verify that the maintenance program and its implementation meet the standards set forth in 10 CFR 50 and supporting documents, and to ensure safe power plant operation from a maintenance perspective.

The inspection findings were discussed with yourself and other members of your staff at the conclusion of the inspection.

Overall, the inspectors concluded that the maintenance program at Ginna was effective and designed to provide very good preventive, predictive, and corrective maintenance.

The inspectors also concluded that all personnel, from management to mechanics, were collectively in support of the maintenance program.

Tracking and trending of maintenance activities in planning, performing, and testing of those activities were very well coordinated and performed.

Finally, the inspectors concluded that the maintenance program is being effectively managed to support safe operation at Ginna.

The strong performance noted in this inspection occurred during a period of smooth, relatively trouble-free plant operation.

In 1993-94, whenever maintenance-related problems occurred, they were usually associated with outages, periods of heavy activity.

You are now approaching your 1995 outage, another period of intense activity.

I would encourage you to take measures to assure yourself that your organization is poised to continue high quality maintenance through a rigorous outage.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter and its enclosure will be placed in the NRC Public Document Room.

040012

'7504040222 950324 PDR ADQCK 05000244

PDR

Dr. Robert C. Mecredy March 24, 1995 No reply to this letter is required, but should you have any questions regarding this inspection, please contact me at 610-337-5282.

Sincerely, OrXg&alSit'tt 8. 373.

A. Randolph Blough, Acting Deputy Director Division of Reactor Safety Docket No. 50-244 Enclosure:

NRC Inspection Report No. 50-244/95-01 cc w/encl:

R. Smith, Senior Vice President, Customer Operations Central Records (7 copies)

Director, Energy and Water Division State of New York, Department of Law N. Reynolds, Esquire PUBLIC Nuclear Safety Information Center (NSIC)

D. Screnci, PAO (2) All Inspection Reports NRC Resident Inspector State of New York, SLO Designee bcc w/encl:

Region I Docket Room (with concur rences)

J. Wiggins, DRS W. Lazarus, DRP S. Stewart, DRP M. Oprendek, DRP DRS File bcc w/encl (VIA E-NAIL):

A. Johnson, PM, NRR W. Dean, OEDO T. Harsh, NRR Inspection Program Branch, NRR (IPAS)

M. Campion, ORA DOCUMENT NAME:

A: G IN9501. INS To receire a copy ofthis document, indicate in the hoxt 'C'

Copy without attachment/enclosure

'E'

Copy with attachment/enclosure

"N'

No copy OFFICE RI/DRS RI/DRS RI/

RI/

RI/

NAME TKENNY GMEYER TE 03/24/95 03/

/95 03/

/95 OFFICIAL RECORD COPY 03/

/95 03/

/95