July 15, 2016
SUBJECT:
GENERAL ELECTRIC - U.S. NUCLEAR REGULATORY COMMISSION ROUTINE, ANNOUNCED INSPECTION REPORT NO. 50-73/2016-201
Dear Mr. Caine:
From June 13-16, 2016, the U.S. Nuclear Regulatory Commission (NRC, or Commission)
conducted a routine, announced inspection at the General Electric Vallecitos Nuclear Center.
The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspection.
This inspection was an examination of activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, no safety concern or non-compliance with NRC requirements was identified. No response to this letter is required.
In accordance with Title 10 of the Code of Federal Regulations Section 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Should you have any questions concerning this inspection, please contact Ossy Font at 301-415-2490 or by electronic mail at Ossy.Font@nrc.gov.
Sincerely,
/RA by William Schuster for/
Anthony J. Mendiola Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
Docket No. 50-73 License No. R-33
Enclosure:
As stated
cc: See next page
Docket No. 50-73
cc:
Mark Leik, Manager Regulatory Compliance GE Hitachi Nuclear Energy Americas LLC Vallecitos Nuclear Center Nuclear Test Reactor 6705 Vallecitos Road Sunol, CA 94586
Dan Thomas, Manager NTR GE Hitachi Nuclear Energy Americas LLC Vallecitos Nuclear Center Nuclear Test Reactor 6705 Vallecitos Road Sunol, CA 94586
Scott Murray, Manager Facility Licensing GE Hitachi Nuclear Energy Americas LLC 3901 Castle Hayne Road Wilmington, NC 28401
Commissioner California Energy Commission 1516 Ninth Street, MS-34 Sacramento, CA 95814
Chief California Department of Health Radiologic Health Branch P.O. Box 997414, MS 7610 Sacramento, CA 95899
Test, Research and Training Reactor Newsletter P.O. Box 118300 University of Florida Gainesville, FL 32611
- concurrence via e-mail NRC-002 OFFICE NRR/DPR/PROB NRR/DPR/PROB/LA*
NRR/DPR/PROB/BC NAME OFont NParker AMendiola (WSchuster for)
DATE 7/15/16 7/15/16 7/15/16
U. S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION
Docket No:
50-73
License No:
R-33
Report No:
50-73/2016-201
Licensee:
General Electric Company
Facility:
Nuclear Test Reactor
Location:
Sunol, CA
Dates:
June 13-16, 2016
Inspector:
Approved by:
Anthony J. Mendiola, Chief
Research and Test Reactor Oversight Branch
Division of Policy and Rulemaking
Office of Nuclear Reactor Regulation
EXECUTIVE SUMMARY
General Electric Vallecitos Nuclear Center NRC Inspection Report No. 50-73/2016-201
The primary focus of this routine, announced inspection was the onsite review of selected aspects of the General Electric Company (GE, the licensee) Class II research reactor facility safety programs including: (1) procedures; (2) radiation protection program; (3) design changes; and (4) violation follow up. The licensees programs were acceptably directed toward the protection of public health and safety, and were in compliance with the U.S. Nuclear Regulatory Commission (NRC) requirements.
Procedures
- Procedure administrative review, revision, adherence to, and implementation satisfied Technical Specification (TS) requirements.
Radiation Protection Program
- The Radiation Protection Program and as low as reasonable achievable programs satisfied regulatory requirements.
Design Changes
- Design changes were made in accordance with Title 10 of the Code of Federal Regulations 50.59, Changes, tests and experiments, requirements, TS, and licensee procedures.
Non-Cited Violation and Requalification Program
- A Severity Level IV non-cited violation was identified for the operation of the reactor by two individuals with expired operator licenses.
Enclosure REPORT DETAILS
Summary of Facility Status
The General Electric Companys (GE, the licensees) 100 kilowatt research reactor has been operated in support of neutron radiography, reactor operator training, and periodic equipment surveillances. During the inspection the reactor was not operated due to a maintenance activity taking place.
1.
Procedures
a.
Inspection Scope (IP 69001)
To ensure that the requirements of Technical Specification (TS) 6.4, Procedures, were being met, the inspector reviewed the following:
- Standard Operating Procedure (SOP) 9.4, Change Authorization, Revision (Rev.) 16, dated June, 6, 2016
Change Authorization (CA) 1022-SOP 6-7, Startup Summary, dated January 7, 2016
CA 1020- SOP 7-5, Radiation Exposure Limits and Controls, dated May 14, 2015
CA 1024-6.1, Staff Requirements, dated June 6, 2016
GE Vallecitos Nuclear Center (VNC) Vallecitos Safety Standards (VSS),
Various
GE VNC Annual Report for the GE-Hitachi Nuclear Test Reactor (NTR) for the past two years
b.
Observations and Findings
Records showed that procedures for TS required items were available. Changes were made for clarification. One change addressed operator distractions, the root cause of the two scrams that occurred in 2015. The licensee maintained approved procedures to satisfy the requirements of the TS.
c.
Conclusion
Procedure administrative review, revision, adherence to, and implementation satisfied TS requirements.
2.
Radiation Protection Program
a.
Inspection Scope (IP 69001)
To ensure the requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 20, Standards for Protection Against Radiation, TSs 3.2, 3.4, 4.2, 4.4, and 6.3 requirements were being met, the inspector reviewed the following
- 2 -
Committee for the past two years
GE VNC dosimetry records for the past two year, Annual Radiation Protection Program Review for the past two years
Radiological training records for the past two years
Survey results for daily, weekly, monthly, routine, and special surveys for the past two years
Respirator Fit Test and Self Contained Breathing Apparatus Training for the past two years
Calibration and periodic check records for radiation monitoring instruments for the past two years
GE VNC VSS, Various
GE VNC Annual Report for the GE-Hitachi NTR for the past two years
Form VNC-699, Request for Additional Exposure, dated September 2011
b.
Observations and Findings
The inspector toured the facility and interviewed licensee personnel, observing practices regarding the use of dosimetry, radiation monitoring equipment, and placement of radiological postings and barriers and determined that they were appropriate.
The licensee used a National Voluntary Laboratory Accreditation Program-accredited vendor to process personnel dosimetry. Radiation work permits were used for all activities to track workers and dose sources with appropriate alarm set points depending on each different area. Due to the reduced staffing levels, exposure amounts have increased for the two active license holders, though one is receiving the majority of the increase as the primary reactor operator. The facility has an administrative limit of 300 millirem/quarter. On occasion, a request for additional exposure has been submitted and approved. The inspector noted that, even with these increases, doses were well within the regulatory limits and consistent with the operations of the NTR.
The licensees Radiation Protection Program (RPP) was established through various standards and procedures in use at the facility. These were maintained and available on-line. The program included requirements that all personnel who performed work in association with radioactive material receive training in radiation protection, policies, procedures, requirements, and facilities. These were being tracked on-line and completed at the required frequency.
Additionally, the annual review of the RPP was being completed internally by different managers at the required frequency.
The inspector reviewed survey and calibration records and found that they were being completed as required with no safety issues identified. The inspector also observed surveys being performed and found the process appropriate. Copies of current notices to workers were posted in the facility.
- 3 -
The inspector reviewed the records documenting on-site and off-site effluent and environmental monitoring stations for the past two years. Airborne and water releases were below regulatory limits. Off-site samples indicated normal background.
c.
Conclusion
The inspector determined that the RPP and ALARA programs satisfied regulatory requirements.
3.
Design Changes
a.
Inspection Scope (IP 69001)
To ensure the requirements of 10 CFR 50.59, Changes, tests and experiments, the TS, and the licensees administrative procedures were being met, the inspector reviewed the following:
- GE VNC Annual Report for the GE-Hitachi NTR for the past two years
SOP 1.2, Primary Makeup System, dated October 11, 1994
SOP 9.4, Change Authorization, Rev. 16, dated June, 6, 2016
CA 309-Safety Rod Magnets
CA 307-Change in Material used in the Primary Makeup System, dated June 3, 2015
SOP 9.3, Engineering Releases, Rev. 992
ER numbers (Nos.) 16-10- Test and Acceptance of Safety Rod No. 1 Magnet Repairs, dated June 14, 2016
ER Nos. 15-09-Repair of Leak in the Primary Makeup System, dated June 3, 2015
10 CFR 50.59, Determination Worksheet
Safety Rod No. 1 Magnet Assembly Repair
Change in Material used in the Primary Makeup System
b.
Observations and Findings
During the inspection, the licensee conducted a maintenance activity to repair one of the safety rod magnet assemblies. Testing was performed and results correlated with previous data. All changes were reviewed and approved by the Senior Reactor Operator/NTR Manager, Regulatory Compliance, Vallecitos Technological Safety Council, and the VNC Site Manager as required.
c.
Conclusion
Design changes were made in accordance with 10 CFR 50.59 requirements, TS, and licensee procedures.
- 4 -
4.
Non-Cited Violation Follow up
a. Inspection Scope (IP 69001)
The inspector reviewed selected aspects of the following to review a self-identified violation.
- Condition Report 18665
NTR Console Log Books, dated from November 10, 2015, to present
NTR Daily Surveillance Check Sheets, from January 6, 2016, to March 10, 2016
NRC Inspection Report No. 50-073/2015-201
b. Observations and Findings
The inspector followed up on a licensee-identified issue associated with the operation of the GE-NTR reactor by two individuals with expired operator licenses. The inspector determined that this issue represents a violation of 10 CFR 50.54(k), which requires that an operator licensed pursuant to 10 CFR Part 55, Operators' Licenses, shall be present at the controls at all times during the operation of the facility. Specifically, the operators licenses expired on January 6, 2016, and was not identified until March 10, 2016. The inspector reviewed logs and identified 21 instances of both individuals operating the reactor, either as the primary operator on duty or in relief of another operator, without supervision by a licensed operator. While the individuals had completed the requalification requirements and biennial medical exam, the licensees failed to submit a renewal application to the NRC. The individuals were immediately removed from reactor operator duties and neither license will be renewed for reasons including retirement of one of the individuals.
To address future operator license renewals, corrective action include the inclusion of expiration and renewal dates in the facilitys compliance calendar.
Additionally, the licensee is establishing policy and procedures for managing the requirements of 10 CFR Part 55.
The inspector determined that this issue represents a Severity Level IV violation of 10 CFR 50.54(k) based on example 6.4.d of the NRC Enforcement Policy.
This non-repetitive, licensee-identified, and corrected violation is being treated as a non-cited violation (NCV), consistent with Section 2.3.2.b of the Enforcement Policy (NCV 50-073/2016-201-01).
c. Conclusion
A Severity Level IV non-cited violation was identified for the operation of the reactor by two individuals with expired operator licenses.
- 5 -
5.
Exit Interview
The inspector presented the inspection results to licensee management at the conclusion of the inspection on June 16, 2016. The licensee acknowledged the findings presented and did not identify as proprietary any of the material provided to or reviewed by the inspector during the inspection.
PARTIAL LIST OF PERSONS CONTACTED
Licensee
S. Murray
GEH Manager D. Hart
EHS Senior Vice President M. Leik
EHS and Regulatory Compliance Manager D. Thomas
NTR Manager T. McConnell Senior Reactor Operator J. Ayala
Radiation Safety Officer
Others
M. Kleman
Employees Resource Manager
INSPECTION PROCEDURES USED
IP 69001 Class II Research and Test Reactors IP 86740 Transportation
ITEMS OPENED, CLOSED, AND DISCUSSED
OPENED
50-073/2016-201-01 NCV Reactor operation by two individuals with expired operator licenses.
CLOSED
50-073/2016-201-01 NCV Reactor operation by two individuals with expired operator licenses.
DISCUSSED None
PARTIAL LIST OF ACRONYMS USED
10 CFR Title 10 of the Code of Federal Regulations ALARA As Low As Reasonably Achievable EHS
Environmental Health and Safety GE
General Electric Company GEH
GE Hitachi IP
Inspection Procedure No.
Number NRC
U.S. Nuclear Regulatory Commission NTR
Nuclear Test Reactor Rev.
Revision RPP
Radiation Protection Program SOP
Standard Operating Procedure TS
Technical Specification VNC
Vallecitos Nuclear Center VSS
Vallecitos Safety Standard