August 22, 2014

SUBJECT:

WASHINGTON STATE UNIVERSITY - NRC ROUTINE INSPECTION REPORT

NO. 50-027/2014-201

Dear Dr. Keane:

On July 22-24, 2014, the U.S. Nuclear Regulatory Commission (NRC, the Commission)

completed an inspection at your Washington State University Training, Research, Isotope Production, General, Atomics research reactor located in the Nuclear Radiation Center (Inspection Report No. 50-027/2012-201). The enclosed report documents the inspection results, which were discussed on July 24, 2014, with Dr. Donald Wall, Director of the Nuclear Radiation Center, and other members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.

No response to this letter is required.

In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, Public inspections, exemptions, and requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this inspection, please contact Mike Morlang at 301-415-4092 or by electronic mail at gmm3@nrc.gov.

Sincerely,

/RA by Ossy Font for/

Kevin Hsueh, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.50-027 License No. R-076

Enclosure:

NRC Inspection Report No. 50-027/2014-201 cc w/encl: See next page

Washington State University Docket No. 50-27

cc:

Chair, Reactor Safeguards Committee Nuclear Radiation Center Washington State University P.O. Box 641300 Pullman, WA 99164 - 1300

Mr. Corey Hines Reactor Supervisor, Nuclear Radiation Center Washington State University P.O. Box 641300 Pullman, WA 99164 - 1300

Dr. Jean Cloran Radiation Safety Officer Washington State University P.O. Box 641302 Pullman, WA 99163-1302

Office of the Governor Executive Policy Division State Liaisons Officer P.O. Box 43113 Olympia, WA 98504-3113

Dr. Donald Wall Director, Nuclear Radiation Center Washington State University P.O. Box 641300 Pullman, WA 99164-1300

Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

August 22, 2014

D