IR 05000027/1982001
| ML20058F947 | |
| Person / Time | |
|---|---|
| Site: | Washington State University |
| Issue date: | 07/28/1982 |
| From: | Mcqueen A, Schuster M, Schwan C NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V) |
| To: | |
| Shared Package | |
| ML19262G667 | List: |
| References | |
| 50-027-82-01, 50-27-82-1, NUDOCS 8208030151 | |
| Download: ML20058F947 (2) | |
Text
..
x
..
$
'. a %
., ~
..
.
.
~ +
-
..
.
.
.
The information on this page is considered to be appropriate
,
for public disclosure pursuant to 10 CFR 2.790.
-U.
S. NUCLEAR REGULATORY COMMISSION
REGION V
Report No. 50-27/82-01 (IE-V-513)
Docket No. 50-27 License No. R-76 Safeguards Group Licensee: Washington State University Pullman, Washington 99104 Facility Name:
Nuclear Radiation Center
,
Inspection at:
Pullman, Washington Inspection Conducted: July 19 and 20, 1982 Date of Last Physical Security Inspection Visit: June 9 and 10, 1980
<
Type of Inspection: Unannounced Physical Security Inspectors:
thidult h. b$
n/u M / D e
A. D. McQueen, PhysicaT Security InsDector (/
J Date ' Signed
/%k //A '
m/u/ra
-
C. A. Schwaff, Physical Security Inspector Date Signed Approved by: //h(A 4
'/ #f8V y
M. D. Schuster, Chief, Physical Security Section Date Signed Inspection Summary:
Areas !nspected:
Security Plan; Protection of SNM; Security Organization;
Access Controls; Alarn Systems; Keys and Locks; Communications; Response Procedures; and Protection against Radiological Sabotage.
The inspection involved 14 inspection hours onsite by two inspectors. The inspection was conducted during the day shift period.
Results: The licensee was found to be in compliance with NRC requirements within t e areas examined during the inspection.
'
i
.
0208030151 920720 PDR ADOCK 05000027
O PDR
...... -.
. _ -,,._.
..
.
. _ -
-.--,--,
,-
,.. _.
_ _ _
,.
-