December 19, 2002
SUBJECT:
NRC ROUTINE, ANNOUNCED INSPECTION REPORT NO. 50-20/2002-203
Dear Dr. Bernard:
This letter refers to the inspection conducted on November 4-5, 2002, at your MIT Research Reactor facility. The inspection reviewed the use of the new medical irradiation facility. The enclosed report presents the results of that inspection.
Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, no safety concerns or noncompliances of NRC requirements were identified.
No response to this letter is required.
In accordance with 10 CFR 2.790 of the NRCs "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room) http://www.nrc.gov/reading-rm/adams.html.
Should you have any questions concerning this inspection, please contact Mr. Thomas Dragoun at 610-337-5373.
Sincerely,
/RA/
Patrick M. Madden, Section Chief Research and Test Reactors Section Operating Reactor Improvements Programs Division of Regulatory Improvement Programs Office of Nuclear Reactor Regulation Docket No.: 50-20 License No.: R-37 Enclosure: NRC Inspection Report No. 50-20/2002-203 cc w/enclosure: See next page
Massachusetts Institute of Docket No. 50-20 Technology cc:
City Manager City Hall Cambridge, MA 02139 Department of Environmental Quality Engineering 100 Cambridge Street Boston, MA 02202 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611
December 19, 2002 Dr. John