November 17, 2014

SUBJECT:

PENNSYLVANIA STATE UNIVERSITY - NRC ROUTINE INSPECTION REPORT NO. 50-5/2014-201

Dear Dr. Unlu:

From October 14-17, 2014, the U.S. Nuclear Regulatory Commission (NRC) conducted a routine inspection at your Pennsylvania State University Breazeale Research Reactor facility.

The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspection.

The inspection examined activities conducted under your license as they relate to the conduct of operations and compliance with the Commissions rules, regulations, and with the conditions of your license. The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified and no response to this letter is required.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) Section 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system. The Agencywide Documents and Management System (ADAMS) is accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Should you have any questions concerning this inspection, please contact Mr. Ossy Font at (301) 415-2490.

Sincerely,

/RA Elizabeth Reed for/

Kevin Hsueh, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation

Docket No. 50-5 License No. R-2

Enclosure:

Inspection Report

cc w/ encl: See next page

Pennsylvania State University

Docket No. 50-5

cc:

Mark A. Trump

Associate Director for Operations

Breazeale Nuclear Reactor

Radiation Science and Engineering Center

The Pennsylvania State University

University Park, PA 16802-1504

Mr. Jeffrey A. Leavey, Manager of

Radiation Protection

The Pennsylvania State University

0201 Academic Project BL

University Park, PA 16802

Dr. Neil A. Sharkey

Interim Vice President for Research

of the Graduate School

The Pennsylvania State University

304 Old Main

University Park, PA 16802-1504

Director, Bureau of Radiation Protection

Department of Environmental Protection

P.O. Box 8469

Harrisburg, PA 17105-8469

Test, Research and Training

Reactor Newsletter

P.O. Box 118300

University of Florida

Gainesville, FL 32611-8300