IR 015000020/1997001

From kanterella
Jump to navigation Jump to search
Insp Rept 15000020/97-01 on 971208.No Violations Noted.Major Areas Inspected:Use of Byproduct Matl & Licensee Source Recovery Procedures Re Mqs Insp Svcs,Inc Radiography Source Disconnect on 971208
ML20198L847
Person / Time
Site: 15000020, 015000020
Issue date: 01/08/1998
From: Courtemanche, Johansen J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20198L807 List:
References
15000020-97-01, 15000020-97-1, NUDOCS 9801160135
Download: ML20198L847 (5)


Text

_-_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _

__ _ _ _ _ - _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

i

.

-

U.S. NUCLEAR REGULATORY COMMISSION

'

REGION 1

,

,

Docket No.:

150-00020 License No.:

2012836-01MA Report No.:

97 001 Licensee:

Amersham Corporation Facility:

40 North Avenue i

Burlington, MA 01803 Location:

TOSCO Refining Company,

'

Trainer Refinery 4101 Post Road Trainer, PA 19061

,

Date:

December 8,1097 l

!

Inspectors:

[I~o m_

ouM I a

-

-

Steven Courteminche Health Phys lcist Approved by:

_-

_

Jef.ny M. J#enfon, Acting Chief

.

NLYclear MaterlaWSafety Branch 3

,

I

.

RETURN ORIGINAL TO

.

REGION I-i ESE**s?$$$EI8A28 PDR

,

.,

y.~.

---

..-.._

_.. _. _. _ _ _ ___ _ _ _ _. _ _ _ _ _. _ _ _ _ _ _. _ _.. _.. _ _. _.. _. _... _ _ _ _ _ _

i

.

l

,

!

EXECUTIVE SUMMARY

~

Amersham Corporation NRC Inspection Report 150-00020/97 001

An announced safety inspection of the licensee's activities at a temporary jobsits in f

Trainer, Pennsylvania. The inspection was limited to observations by the inspector, interviews with personnel and sel6ctive examination of records. Areas inspected

were the use of byproduct material and the licensee's source recovery procedures in

relation to the MOS Inspection Services, Inc. (MOS) rad!ography source disconnect c 1

-

December 8,1997. -

,

f

,

.

i

.

.

I

~

.

'

-2-

- 150-00020/97-001

i.

. _. _

=. _ -

-*-w

.,

4..-~,.

,

.-4

- -. -

v-

-,

.~r,

,,,., ~, -.. - - - - - - -,., _.., _.

- -,..

..~--,,,,,..-z

.x--.:,-.,.... -.

-

,,,,,.

-.m

,,

. _. _ _ _

-

_

_

_..

_ _-

._-

_. -

.

.

REPORT DETAILS

'

l. Use of Byproduct Material

,

s.

jnenardon Scone Amersham Corporation (Amersham) is authorized, in part, to perform emergency source retrieval operations at temporary jobsites anywhere in the Commonwealth of Massachusetts (Commonwealth) where the Commonwealth has jurisdiction under Commonwealth License No. 2012836-01 MA.

b.

Qblervations and Findinas Amersham requested and was granted reciprocity by NRC Region 1 (RI) under 10 CFR 150,20 for a general license to perform an emergency source retrieval operation at the Tosco Refinery in Trainer, Pennsylvania on December 8,1997.

The RI staff contacted Amersham representatives for further information on the incident to determine the licensee involved and the circumstances behind the need for the source retriaval.

Amersham personnel were interviewed by the inspector. Pencil dosimeters were determined to be zorood prior to the source retrieval operation, alarming ratemeters, and pencil dosimeters were operational. Amersham personnel demonstrated that they had a good understanding of the company's emergency source retrieval procedures, c.

Conclusions No safety concerns were identified.

11. Source Retrieval Operations a.

Insoection Scooe OWervations by the inspector of Amersham's emergency source retrieval operations and documents required for the shipmer.t of the licensed material back to Amersham'n facilities, b.

Observations and Findinas The inspector interviewed personnel, observed the source retrieval operation, and reviewed the documents necessary for Amersham to perform the operation under reciprocity and ship the licensed material back to their facility.

The Assistant Radiatier. Safety Officer (ARSO) for the client (MOS) described, to the inspector, the spearance of the.end of the drive cable as being sheared off with a few strands of frayed cable sticking out. The break occurred just behind the mating attachment of the drive cable.

-3-150 00020/97 001 s

1 -

- --

.

.

The inspector performed confirmatory surveys using a Ludlum 14C, End Window Geiger Mueller survey meter (Serial Number 19614) and a Ludlum 19 MicroR survey meter Serial Number 15521). The Ludlum 14C radiation level measurements were in agreement with the licensee's while the Ludlum 19's radiation level measurements were higher. (i.e.,1.7 millirem / hour maximum versus 3.5 millirem / hour maximum) at the boundaries. The inspector interviewed MOS personnel and determined that no unauthorized personnel approached the boundaries. The above was confirmed by the inspector by interviewing TOSCO personnel.

The source retrieval company arrived on-site at 7:45 p.m. A conference was called to brief all personnel as to what to expect and the responsibilities of all parties. The area around the source was secured by MOS personnel and all unauthorized personnel were removed to shielded areas, the source was recovered at 10:45 p.m. and placed in an Amersham Tech Ops 680L source changer for transport back to Amersham's facilities. Amersham personnel stated that the drive cable would be examined to determine what may have caused the source disconnect. The inspector determined that Amersham personnel possessed the proper documents permitting them to perform the source retrieval operation and the shipment of the licensed material back to Amersham's facilities.

Estimates of radiation exposures to personnel, according to self reading pocket dosimeters were:

MQG Personnel ARSO 20 millirem Radiographer iG millirem Assistant radiographer 5 millirem Amersham personnel 300 millirem to the lens of the eye, less to the whole body c.

Conclusions No safety concerns were identified.

-4-150 00020/97-001 g

_

-

_

,_.

__

_

_

. _ _...

-

_.

... _. _ __._.

  • r

,

!

PARTIAL LIST Or PERSONS CONTACTED

'

!

MQS Inspection Services. Inc.

  • William Trump, Supervisor William Batting, Assistant Radiation Safety Officer

-

Randall Harpold,~ District Manager Tosco Refinina Comoany Mary Wiggins, Ridistion Safety Officer John J. Hollen, Business Team Leader-Angelo Zuillutti, Shift Supervisor Amersham Corooration

-

Robert L. Kelley, Technical Support Specialist

,

i

,

?

,

,

t 5-150-00020F. J1

>

,

I

3g

,

,

-

-, - -,,

~. U rn.


,

n w

-