FEB-21-2018 07:19 FROM:BAILEY-ORYSIA 864+427+1032 T0:16106803497 NRC FQ,RM 591NI PART 1 (07~12)'
10 CFR 2.201 U.S. NUCLEAR REGULATORY COMMISSION SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION 1. LICENSEE/LOCATION INSPl=CTEO:
2. NRC/REGIONAL OFFICE URS Federal Services. In P.O. Box 21025 Kennedy Space Center, FL 32815 REPORT NUMBER($)
3. DOCKET NUMBER(S)
15000009 LICENSEE:
15000009.2018001
4. LICENSE NUMBER($)
FL 4449~1 U.S. Nuclear Regulatory Commission Region I, 2100 Renaissance Blvd, Suite 100 King of Prussia, Pennsylvanla 19406-2713
5. DATE(S) OF INSPECTION February 8, 2018
'fhe insp9ction was an examination of the activities conducted under your license as they relate to radiation Gafety and to compllance with the Nuclear Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures anc:1 representative records, interviews with personnel, and observations by the inspector. The inspection findings are as follow&:
Ix/
[]
n LJ 1. Based on the Inspection findings, no violations were Identifie PreviOU$ violation(&) close. The violation(s), specifically described to you by the inspector as non-cited violations,.ire not being cited because they were self*
identified, non-repetitive, and corrective action was or is being taken, and the remaining criteria In the NRC Enforcement Polley, to exercise discretion, were satisfie Non-cited violation(s) were discussed lnvolvlng ttle following requlrement(s) and correcttve actlon(s):
4. Curing this Inspection, certain of your activities, as dtiscribed below and/or attached, were in violation of NRC requirements and are being cited in accordance with the NRC Enforcement Polley. This forrn is a NOTICE; OF VIOi.A TION, which may be subject to posting In accordance witl'l 1 o CFR 19.11. (Violations and Corrective Actions)
Statement of Corrective Actions I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations Identified. This statement of corrective actions is made in accordance with the requirements of 10 CFR 2.201 (corrective steps already taken, corrective steps which will be taken, dale when full compliance will be achieved). I understand that no further written response to NRC will be required, unless specifically requeste Title
- -**----~-------.. -----*
PtlntQd Name Slgnatur.!..,... ---+---D_a_te;;..__-1 LICENSEE'S REPRESENTATIVE NRC INSPECTOR V
-
- NRC FORM 591 M PART 1 (07,2012) (RI Rov. 09112/2013)
G:\\ONMS\\WordOocslCurrent\\lnap Record\\R 15000009.2018001. 591 M*Part1.doc SUNSI Review Completed By:
OMS ~
____...,. _____________ _ [!] Public 0 Non-Sensitive This dot11111e111 becornci an NRC Official Aeency Rcco1*d 011cc Ir I~ slg1ml by the Bn1ni:h Chl1:t