Category:Annual Report
MONTHYEARML23132A1532023-05-12012 May 2023 Transmittal of 2022 Annual Financial Reports ML22116A2612022-04-26026 April 2022 Operating Corp - Transmittal of 2021 Annual Financial Reports ML21127A2482021-05-0707 May 2021 Operating Corp - Transmittal of 2020 Annual Financial Reports ML20129K0332020-05-0707 May 2020 Transmittal of 2019 Annual Financial Reports ML17132A1722017-05-0303 May 2017 Transmittal of 2016 Annual Financial Reports ML16133A4392016-05-0404 May 2016 Transmittal of 2015 Annual Reports for Westar Energy, Great Plains Energy Incorporated, and Kansas Electric Power Cooperative, Inc ML15133A2202015-05-0505 May 2015 Kansas Electric Power Cooperative, Inc., 2014 Annual Report ML15133A2192015-05-0505 May 2015 Great Plains Energy 2014 Annual Report ML15133A2182015-05-0505 May 2015 Westar Energy 2014 Annual Report ML14133A1462014-05-0606 May 2014 Transmittal of 2013 Annual Financial Reports ML13151A2742012-12-31031 December 2012 Kansas Electric Power Cooperative, Inc., 2012 Annual Report ML13151A2752012-12-31031 December 2012 Westar Energy, 2012 Annual Report ML13151A2732012-12-13013 December 2012 Great Plains Energy 2012 Annual Report ML12138A0422012-05-0808 May 2012 Operating Corp. - Transmittal of 2011 Annual Financial Reports, Including Westar Energy 2011 Annual Report, Great Plains Energy 2011 Annual Report and Kansas Electric Power Cooperative, Inc. Annual Report 2011 ML1012602142010-04-28028 April 2010 Westar Energy, 2009 Annual Financial Report ML1012602172010-04-28028 April 2010 Great Plains Energy Incorp., 2009 Annual Financial Report ML1012602162010-04-28028 April 2010 Kansas Electric Power Cooperative, Inc., 2009 Annual Financial Report ML0913903422009-05-0707 May 2009 Transmittal of 2008 Annual Financial Reports ML0814301022008-05-0909 May 2008 Operating Corporation - Transmittal of 2007 Annual Financial Reports ML0714402252007-05-14014 May 2007 Transmittal of 2006 Annual Financial Reports ML0616503722006-06-0808 June 2006 Transmittal of 2005 Annual Financial Reports ML0612301102006-04-27027 April 2006 Annual Radiological Environmental Operating Report ML0514500852005-05-18018 May 2005 Transmittal of 2004 Annual Financial Reports ML0510404282005-04-0808 April 2005 2004 Annual Environmental Operating Report ML0512403392004-12-31031 December 2004 Annual Radioactive Effluent Release Report, Report 28, 01/01/2004 Through 12/31/2004 ML0429500862003-12-31031 December 2003 Report No. 27, Annual Radioactive Effluent Release Report, January 1, 2003 - December 31, 2003. ML0312700352003-04-29029 April 2003 Annual Financial Reports for Great Plains Energy, Inc and Kansas City Power & Light Co, in the State of Missouri ML0312700532003-04-29029 April 2003 Kansas Electric Power Cooperativve, Inc Financial Statements for Years Ended December 31, 2002 and 2001 ML0312700282003-04-29029 April 2003 Annual Financial Reports for Westar Energy, Inc, in the State of Kansas ML0307807212003-03-11011 March 2003 Annual 50.59 Evaluation Report WM 02-0016, Transmittal of 2001 Annual Financial Reports2002-05-0606 May 2002 Transmittal of 2001 Annual Financial Reports ET 02-0016, Annual Report of ECCS Model Changes2002-03-20020 March 2002 Annual Report of ECCS Model Changes 2023-05-12
[Table view] Category:Letter type:ET
MONTHYEARET 23-0006, CFR 50.55a Request Number CI3R-01 for the Third Containment Inservice Inspection Program Interval for Proposed Alternative Frequency to Containment Unbonded Post-Tensioning System Components2023-05-17017 May 2023 CFR 50.55a Request Number CI3R-01 for the Third Containment Inservice Inspection Program Interval for Proposed Alternative Frequency to Containment Unbonded Post-Tensioning System Components ET 23-0005, 10 CFR 50.55a Request Number I4R-08 for the Fourth Inservice Inspection Program Interval, Relief for Extension of Follow Up Examination Requirements for Reactor Pressure Vessel Head Penetration Nozzles with Mitigated Alloy 600/82/182 Peen2023-03-16016 March 2023 10 CFR 50.55a Request Number I4R-08 for the Fourth Inservice Inspection Program Interval, Relief for Extension of Follow Up Examination Requirements for Reactor Pressure Vessel Head Penetration Nozzles with Mitigated Alloy 600/82/182 Peened ET 23-0003, License Amendment Request (LAR) for Removal of the Power Range Neutron Flux Rate - High Negative Rate Trip Function from Technical Specifications2023-03-0101 March 2023 License Amendment Request (LAR) for Removal of the Power Range Neutron Flux Rate - High Negative Rate Trip Function from Technical Specifications ET 23-0002, Supplement to License Amendment Request to Adopt TSTF-577-A, Revision 1, Revised Frequencies for Steam Generator Tube Inspections2023-02-0707 February 2023 Supplement to License Amendment Request to Adopt TSTF-577-A, Revision 1, Revised Frequencies for Steam Generator Tube Inspections ET 23-0004, Response to Requests for Additional Information (RAI) Regarding License Amendment Request (LAR) for Deviation from Fire Protection Program Requirements2023-01-26026 January 2023 Response to Requests for Additional Information (RAI) Regarding License Amendment Request (LAR) for Deviation from Fire Protection Program Requirements ET 22-0006, Operating Corp. - Application to Revise Technical Specifications to Adopt TSTF-577-A, Revision 1, Revised Frequencies for Steam Generator Tube Inspections2022-12-0101 December 2022 Operating Corp. - Application to Revise Technical Specifications to Adopt TSTF-577-A, Revision 1, Revised Frequencies for Steam Generator Tube Inspections ET 22-0010, License Amendment Request (LAR) for Deviation from Fire Protection Program Requirements2022-08-0202 August 2022 License Amendment Request (LAR) for Deviation from Fire Protection Program Requirements ET 22-0012, Supplement to License Amendment Request - Diesel Generator Completion Time Extension for Technical Specification 3.8.1, AC Sources - Operating2022-07-12012 July 2022 Supplement to License Amendment Request - Diesel Generator Completion Time Extension for Technical Specification 3.8.1, AC Sources - Operating ET 22-0011, Withdrawal of 10 CFR 50.55a Request I4R-08, Relief for Extension of Follow-up Examination and Visual Examination Requirements for Reactor Pressure Vessel Head Penetration Nozzles with Mitigated Alloy 600/82/182 Peened Surface2022-05-31031 May 2022 Withdrawal of 10 CFR 50.55a Request I4R-08, Relief for Extension of Follow-up Examination and Visual Examination Requirements for Reactor Pressure Vessel Head Penetration Nozzles with Mitigated Alloy 600/82/182 Peened Surface ET 22-0005, Response to Request for Additional Information Regarding License Amendment Request - Diesel Generator Completion Time Extension for Technical Specification 3.8.1, AC Sources - Operating2022-04-13013 April 2022 Response to Request for Additional Information Regarding License Amendment Request - Diesel Generator Completion Time Extension for Technical Specification 3.8.1, AC Sources - Operating ET 22-0003, CFR 50.55a Request I4R-09 for the Fourth Inservice Inspection Program Interval, Relief from Examination of Reactor Vessel Flange Threads2022-04-0606 April 2022 CFR 50.55a Request I4R-09 for the Fourth Inservice Inspection Program Interval, Relief from Examination of Reactor Vessel Flange Threads ET 22-0002, Operating Corp 10 CFR 50.55a Request Number I4R-08 for the Fourth Inservice Inspection Program Interval, Relief for Extension of Follow Up Examination and Visual Examination Requirements for Reactor Pressure Vessel Head .2022-04-0404 April 2022 Operating Corp 10 CFR 50.55a Request Number I4R-08 for the Fourth Inservice Inspection Program Interval, Relief for Extension of Follow Up Examination and Visual Examination Requirements for Reactor Pressure Vessel Head . ET 22-0004, Operating Corp - Response to Request for Confirmation of Information (RCI) Regarding Steam Generator Tube Inspection Report2022-03-15015 March 2022 Operating Corp - Response to Request for Confirmation of Information (RCI) Regarding Steam Generator Tube Inspection Report ET 22-0001, Removal of the Table of Contents from the Technical Specifications2022-01-12012 January 2022 Removal of the Table of Contents from the Technical Specifications ET 21-0017, Response to Request for Additional Information Regarding License Amendment Request - Revision to Technical Specification 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation2021-12-22022 December 2021 Response to Request for Additional Information Regarding License Amendment Request - Revision to Technical Specification 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation ET 21-0009, Results of the Steam Generator Tube Inservice Inspection During the 24th Refueling Outage2021-11-0101 November 2021 Results of the Steam Generator Tube Inservice Inspection During the 24th Refueling Outage ET 21-0015, Withdrawal of License Amendment Request for a Risk-Informed Resolution to GSI-1912021-10-20020 October 2021 Withdrawal of License Amendment Request for a Risk-Informed Resolution to GSI-191 ET 21-0012, Supplement to License Amendment Request for a Risk-Informed Resolution to GSI-1912021-10-11011 October 2021 Supplement to License Amendment Request for a Risk-Informed Resolution to GSI-191 ET 21-0004, License Amendment Request - Diesel Generator Completion Time Extension for Technical Specification 3.8.1, AC Sources - Operating2021-09-29029 September 2021 License Amendment Request - Diesel Generator Completion Time Extension for Technical Specification 3.8.1, AC Sources - Operating ET 21-0010, License Amendment Request - Revision to Technical Specification 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation2021-09-29029 September 2021 License Amendment Request - Revision to Technical Specification 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation ET 21-0005, Operating Corp., License Amendment Request for a Risk-Informed Resolution to GSI-1912021-08-12012 August 2021 Operating Corp., License Amendment Request for a Risk-Informed Resolution to GSI-191 ET 20-0013, Response to Request for Additional Information Re Application for Technical Specification Change Re Risk-Informed Justification for Relocation of Specific Surveillance Frequency Requirements to Licensee Controlled Program (TSTF-415)2020-10-26026 October 2020 Response to Request for Additional Information Re Application for Technical Specification Change Re Risk-Informed Justification for Relocation of Specific Surveillance Frequency Requirements to Licensee Controlled Program (TSTF-415) ET 20-0011, Request to Use a Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI2020-10-0101 October 2020 Request to Use a Provision of a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI ET 20-0007, License Amendment Request for Replacement of Engineered Safety Features Transformers with New Transformers That Have Active Automatic Load Tap Changers2020-06-0808 June 2020 License Amendment Request for Replacement of Engineered Safety Features Transformers with New Transformers That Have Active Automatic Load Tap Changers ET 20-0008, Operating Corporation Update for Full Implementation of Open Phase Detection System2020-05-20020 May 2020 Operating Corporation Update for Full Implementation of Open Phase Detection System ET 20-0004, Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program (TSTF-425)2020-04-27027 April 2020 Application for Technical Specification Change Regarding Risk-Informed Justification for the Relocation of Specific Surveillance Frequency Requirements to a Licensee Controlled Program (TSTF-425) ET 20-0002, Response to Request for Additional Information Regarding Utilizing Code Case N-666-1, Weld Overlay of Class 1, 2, and 3 Socket Welded Connections, Section XI, Division 12020-01-29029 January 2020 Response to Request for Additional Information Regarding Utilizing Code Case N-666-1, Weld Overlay of Class 1, 2, and 3 Socket Welded Connections, Section XI, Division 1 ET 19-0021, Errata for Supplemental Response to Request for Additional Information Revision to Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation2019-12-0909 December 2019 Errata for Supplemental Response to Request for Additional Information Revision to Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation ET 19-0020, Supplemental Response to Request for Additional Information Revision to Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation2019-11-13013 November 2019 Supplemental Response to Request for Additional Information Revision to Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation ET 19-0019, Response to Request for Additional Information Revision to Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation.2019-09-10010 September 2019 Response to Request for Additional Information Revision to Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation. ET 19-0018, Supplement to License Amendment Request to Revise Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation.2019-08-22022 August 2019 Supplement to License Amendment Request to Revise Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation. ET 19-0014, lnserv1ce Inspection (ISI) Program Relief Request Number 14R-07, to Utilize Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, D1v1s1on 12019-08-15015 August 2019 lnserv1ce Inspection (ISI) Program Relief Request Number 14R-07, to Utilize Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, D1v1s1on 1 ET 19-0002, License Amendment Request to Revise Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation.2019-03-18018 March 2019 License Amendment Request to Revise Technical Specification 3.3.5, Loss of Power (LOP) Diesel Generator (DG) Start Instrumentation. ET 19-0008, Response to Request for Additional Information Related to Thermal Conductivity Degradation for License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analysis Including Adoption.2019-03-0505 March 2019 Response to Request for Additional Information Related to Thermal Conductivity Degradation for License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analysis Including Adoption. ET 19-0003, License Amendment Request to Revise Technical Specification 3.6.3 and Surveillance Requirement 3.6.3.1 to Remove Use of a Blind Flange2019-02-25025 February 2019 License Amendment Request to Revise Technical Specification 3.6.3 and Surveillance Requirement 3.6.3.1 to Remove Use of a Blind Flange ET 19-0001, Application to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 42019-01-23023 January 2019 Application to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules, Revision 4 ET 18-0032, Operating Corporation Change of Date for Full Implementation of Open Phase Detection System2018-12-0707 December 2018 Operating Corporation Change of Date for Full Implementation of Open Phase Detection System ET 18-0035, Operating Corp., Supplemental Response to RAI for License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analysis Including Adoption of Alternative Source Term2018-12-0606 December 2018 Operating Corp., Supplemental Response to RAI for License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analysis Including Adoption of Alternative Source Term ET 18-0029, (WCGS) - Results of the Twenty First Steam Generator Tube Inservice Inspection2018-10-31031 October 2018 (WCGS) - Results of the Twenty First Steam Generator Tube Inservice Inspection ET 18-0018, Supplement to License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analysis Including Adoption of Alternative Source Term2018-06-19019 June 2018 Supplement to License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analysis Including Adoption of Alternative Source Term ET 18-0016, Response to Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools Request for Supplemental Information2018-05-29029 May 2018 Response to Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools Request for Supplemental Information ET 18-0014, Response to Request for Additional Information Regarding the License Amendment Request for Addition of New Technical Specification 3.7.20, Class 1E Electrical Equipment Air Conditioning (A/C) System.2018-05-29029 May 2018 Response to Request for Additional Information Regarding the License Amendment Request for Addition of New Technical Specification 3.7.20, Class 1E Electrical Equipment Air Conditioning (A/C) System. ET 18-0013, Relief Request Number I4R-06, Request for Relief from ASME Code Case N-729-4 for Reactor Vessel Head Penetration Nozzle Weld2018-05-0202 May 2018 Relief Request Number I4R-06, Request for Relief from ASME Code Case N-729-4 for Reactor Vessel Head Penetration Nozzle Weld ET 18-0011, (WCGS) - Guarantee of Payment of Deferred Premiums2018-04-30030 April 2018 (WCGS) - Guarantee of Payment of Deferred Premiums ET 18-0012, Operating Corp., Supplement to License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analysis Including Adoption of Alternative Source Term2018-04-19019 April 2018 Operating Corp., Supplement to License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analysis Including Adoption of Alternative Source Term ET 18-0010, Financial Protection Levels2018-03-29029 March 2018 Financial Protection Levels ET 18-0007, Supplement to License Amendment Request for Addition of New Technical Specification 3.7.20, Class 1E Electrical Equipment Air Conditioning (A/C) System.2018-02-15015 February 2018 Supplement to License Amendment Request for Addition of New Technical Specification 3.7.20, Class 1E Electrical Equipment Air Conditioning (A/C) System. ET 18-0005, Withdrawal of License Amendment Request for Revision to the Emergency Plan2018-02-0505 February 2018 Withdrawal of License Amendment Request for Revision to the Emergency Plan ET 18-0004, Supplement to License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analysis Including Adoption of Alternative Source Term2018-01-29029 January 2018 Supplement to License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analysis Including Adoption of Alternative Source Term ET 17-0025, Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analyses Including Adoption of Alternative Source Term2017-11-14014 November 2017 Response to Request for Additional Information Regarding License Amendment Request to Revise Technical Specifications to Transition to Westinghouse Core Design and Safety Analyses Including Adoption of Alternative Source Term 2023-05-17
[Table view] |
Text
W~LF CREEK'NUCLEAR OPERATING CORPORATION Richard A. Muench Vice President Technical Services MAR 2 0 2002 ET 02-0016 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555
Reference:
Westinghouse Letter SAP-02-6, dated March 4, 2002, Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station Unit 1, 10 CFR 50.46 Annual Notification and Reporting for 2001
Subject:
Docket No. 50-482: 10 CFR 50.46 Annual Report of ECCS Model Changes Gentlemen:
This letter provides the annual report for the Emergency Core Cooling System (ECCS)
Evaluation Model changes and errors for the 2001 model year that affect the Peak Cladding Temperature (PCT) for the Wolf Creek Generating Station (WCGS). This letter is provided in accordance with the criteria and reporting requirements of 10 CFR 50.46(a)(3)(ii), as clarified in Section 5.1 of WCAP-13451, "Westinghouse Methodology for Implementation of 10 CFR 50.46 Reporting." Regulation 10 CFR 50.46(a)(3)(ii) states, in part, "For each change to or error discovered in an acceptable evaluation model or in the application of such a model that affects the temperature calculation, the applicant or licensee shall report the nature of the change or error and its estimated effect on the limiting ECCS analysis to the Commission at least annually as specified in section 50.4. If the change or error is significant, the applicant or licensee shall provide this report within 30 days and include with the report a proposed schedule for providing a reanalysis or taking other action as may be needed to show compliance with section 50.46 requirements."
Wolf Creek Nuclear Operating Corporation (WCNOC) has reviewed the notification of 10 CFR 50.46 reporting information pertaining to the ECCS Evaluation Model changes that were implemented by Westinghouse for 2001 as described in the above Reference. The review concludes that the effect of changes to, or errors in, the Evaluation Models on the limiting transient PCT is not significant for 2001. Therefore, the report of the ECCS Evaluation Model changes is provided on an annual basis.
/ Phone: (620) 364-8831 P.O. Box 411 / Burlington, KS 66839 An Equal Opportunity Employer M/F/HCNVET
ET 02-0016 Page 2 of 2 Attachment I provides an assessment of the specific changes and enhancements to the Westinghouse Evaluation Models for 2001. These model changes and enhancements do not have impacts on the PCT and will generally not be presented on the PCT rack-up forms.
Attachment II provides the calculated Large Break Loss of Coolant Accident (LOCA) and Small Break LOCA PCT margin allocations in effect for the 2001 WCGS evaluation models. There were no changes made for 2001 that impact the PCT effect for 10 CFR 50.46 reporting purposes. The PCT values determined in the Small Break and Large Break LOCA analysis of record, combined with all of the PCT allocations, remain well below the 10 CFR 50.46 regulatory limit of 2200 degrees Fahrenheit. Therefore, WCGS is in compliance with 10 CFR 50.46 requirements and no reanalysis or other action is required.
No commitments are identified in this correspondence.
If you have any questions concerning this matter, please contact me at (620) 364-4034, or Mr.
Tony Harris at (620) 364-4038.
Very truly yours, Richard Muench RAM/pb Attachment I - Assessment of Changes to the Westinghouse Emergency Core Cooling System (ECCS) Evaluation Models for Large and Small Break Loss of Coolant Accidents (LOCA)
Attachment II - Emergency Core Cooling System (ECCS) Evaluation Model Peak Cladding Temperature (PCT) Margin Allocations cc: J. N. Donohew (NRC), w/a D. N. Graves (NRC), w/a E. W. Merschoff (NRC), w/a Senior Resident Inspector (NRC), w/a
Attachment I to ET 02-0016 Page 1 of 4 ASSESSMENT OF CHANGES TO THE WESTINGHOUSE EMERGENCY CORE COOLING SYSTEM (ECCS) EVALUATION MODELS FOR LARGE AND SMALL BREAK LOSS OF COOLANT ACCIDENTS (LOCA)
REFILL Hot Wall Delay Model Generic Input Values
Background
Various discrepancies were identified in the generic input values that are used with the REFILL hot wall delay model, which is presently incorporated as a module in BASH.
This issue was resolved by replacing the use of generic values with expressions that were derived based on the IMP database and utilize appropriate plant-specific information. These changes were determined to be a closely related group of Non Discretionary Changes in accordance with Section 4.1.2 of WCAP-1 3451.
Affected Evaluation Models 1981 Westinghouse Large Break LOCA Evaluation Model 1981 Westinghouse Large Break LOCA Evaluation Model with BART 1981 Westinghouse Large Break LOCA Evaluation Model with BASH Estimated Effect In a typical PWR calculation, the hot wall delay period represents a very minor portion of the large break LOCA transient. Replacing the use of generic values with IMP-based expressions was determined to have a negligible effect on results that will be treated as a 0 degree F PCT effect for 10 CFR 50.46 reporting purposes.
LOCBART Rod-Average Oxidation Error
Background
An error was discovered in LOCBART whereby the calculation of the rod-average oxidation incorrectly includes elevations below the bottom of the active fuel. As discussed below, it was determined that correcting this error would either have a negligible effect on, or would result in a reduction in, the rod-average oxidation, so LOCBART updates will be deferred to a future code release. When corrected, this error correction will represent a Non-Discretionary Change in accordance with Section 4.1.2 of WCAP-13451.
Affected Evaluation Models 1981 Westinghouse Large Break LOCA Evaluation Model with BART 1981 Westinghouse Large Break LOCA Evaluation Model with BASH
Attachment I to ET 02-0016 Page 2 of 4 Estimated Effect For typical near-Beginning of Life (BOL) calculations, correcting this error would have a negligible effect on the rod-average oxidation. For calculations beyond BOL, correcting this error would result in a reduction in the rod-average oxidation. In either case, existing analysis results remain conservative.
Inclusion of Required NOTRUMP Version 38.0 Input Variables in SPADES
Background
Following the release of NOTRUMP Version 38.0, which introduced several new input variables to the Evaluation Model, it became necessary to update the SPADES code to reflect these new input variables. These input variables are required to activate the revised model features incorporated into the NOTRUMP Version 38.0 code. This change was determined to be a Discretionary Change in accordance with Section 4.1.1 of WCAP-1 3451.
Affected Evaluation Models 1985 Westinghouse Small Break LOCA Evaluation Model with NOTRUMP Estimated Effect This change simply introduces the new input parameters required by the release of NOTRUMP Version 38.0 to SPADES. The revised NOTRUMP model PCT effects have previously been assessed, and this change to SPADES does not introduce an additional PCT impact.
Use of NOTRUMP Subcooled Steam Table Routines in SPADES
Background
A review of SPADES calculation methodology determined that subcooled fluid node properties were being calculated based on steam tables that were inconsistent with those of NOTRUMP. As a result, slight differences in fluid node conditions could be seen between SPADES and NOTRUMP. The SPADES code has been modified to utilize the NOTRUMP subcooled steam table properties. This reduces perturbations incurred during the steady-state simulation period with NOTRUMP resulting from differences in subcooled steam table properties. This revision was determined to be a Discretionary Change in accordance with Section 4.1.1 of WCAP-1 3451.
Affected Evaluation Models 1985 Westinghouse Small Break LOCA Evaluation Model with NOTRUMP
Attachment I to ET 02-0016 Page 3 of 4 Estimated Effect The nature of this change leads to an estimated PCT impact of 0 degrees F.
Accumulator Line Friction Factor in the NOTRUMP Evaluation Model Backgqround The current input for the NOTRUMP evaluation model uses a dimensionless value of 0.013 for line loss friction factor in the accumulator injection lines. This is based on fully developed, turbulent flow in the general pipe size range for accumulator injection lines applicable to Westinghouse designed Nuclear Steam Supply Systems. However, in small break LOCA during accumulator injection, the flow seldom obtains velocities high enough to support the fully developed, turbulent flow value. Taking this into account yields a friction factor on the order of 0.016. This revision was determined to be a Discretionary Change in accordance with Section 4.1.1 of WCAP-1 3451.
Affected Evaluation Models 1985 Westinghouse Small Break LOCA Evaluation Model with NOTRUMP Estimated Effect The nature of this change leads to an estimated PCT impact of 0 degrees F.
Improved Code Input/Output and Diagnostics, and General Code Maintenance Backgqround Various changes in code input and output format have been made to enhance usability and help preclude errors in analyses. This includes both input changes (e.g., more relevant input variables defined and more common input values used as defaults) and input diagnostics designed to preclude unreasonable values from being used, as well as various changes to code output which have no effect on calculated results. In addition, various blocks of coding were rewritten to eliminate inactive coding, optimize the active coding, and improve commenting, both for enhanced usability and to facilitate code debugging when necessary. These changes were determined to be Discretionary Changes in accordance with Section 4.1.1 of WCAP-13451.
Affected Evaluation Models 1981 Westinghouse Large Break LOCA Evaluation Model 1981 Westinghouse Large Break LOCA Evaluation Model with BART 1981 Westinghouse Large Break LOCA Evaluation Model with BASH 1975 Westinghouse Small Break LOCA Evaluation Model with WFLASH 1985 Westinghouse Small Break LOCA Evaluation Model with NOTRUMP
Attachment I to ET 02-0016 Page 4 of 4 Estimated Effect The nature of these changes leads to an estimated PCT impact of 0 degrees F.
Attachment II to ET 02-0016 Page 1 of 4 EMERGENCY CORE COOLING SYSTEM (ECCS) EVALUATION MODEL PEAK CLADDING TEMPERATURE (PCT) MARGIN ALLOCATIONS LARGE BREAK LOCA PCT MARGIN UTILIZATION Evaluation Model: 1981 EM with BASH Fuel: 17X17 V5H w/IFM, non-IFBA, 275 psig Peaking Factor: FQ=2.50, FdH=1. 6 5 SG Tube Plugging: 10%
Power Level: 3565 MWth Limiting transient: CD=0.4, Min. SI, Reduced Tavg A. ANALYSIS OF RECORD (Rerating 8/92)
Peak Cladding Temperature (PCT): 1916°F (1)
B. PRIOR PERMANENT ECCS MODEL ASSESSMENTS APCT = 63°F (2)
C. PLANNED PLANT CHANGE EVALUATIONS
- 1. Loose Parts APCT = 20°F (3)
- 2. Containment Purge APCT = 0°F (4)
- 3. Cycle 10 Fuel Assembly Design Changes APCT = 95OF (5)
- 4. Fuel Rod Crud APCT = 0°F (6)
TOTAL PLANNED PLANT CHANGE ASSESSMENTS APCT = 1151F D. 2001 10 CFR 50.46 MODEL ASSESSMENTS (Permanent Assessment of PCT Margin)
- 1. None APCT = 01F E. TEMPORARY ECCS MODEL ISSUES
- 1. None APCT = 0°F F. OTHER MARGIN ALLOCATIONS
- 1. Transition Core Penalty APCT = 0°F (7)
- 2. Cold Leg Streaming Temperature Gradient APCT = 0°F (8)
- 3. Rebaseline of Limiting AOR Case (12/96) APCT = -63 0 F (9)
- 4. Adjustment for LOCBART Zirc-Water Oxidation APCT = -5°F (10)
Error LICENSING BASIS PCT + MARGIN ALLOCATIONS PCT = 2026OF CUMULATIVE ABSOLUTE MAGNITUDE OF PCT CHANGES _IAPCTI = 151F SINCE LAST 30-DAY REPORT (LETTER ET 99-0045)
Attachment II to ET 02-0016 Page 2 of 4 Notes/
References:
- 1. Westinghouse Topical Report WCAP-13456, "Wolf Creek Generating Station NSSS Rerating Licensing Report," October 1992.
- 2. Westinghouse to WCNOC letter SAP-01-105, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, 10 CFR 50.46 Annual Notification and Reporting for 2000," March 6, 2001.
- 3. Westinghouse to WCNOC letter SAP-90-148, "Wolf Creek Nuclear Operating Corporation, RCS Loose Parts Evaluation," April 18, 1998.
- 4. Westinghouse to WCNOC letter SAP-94-102, "Containment Mini purge Isolation Valve Stroke Time Increase," January 12, 1994.
- 5. Westinghouse to WCNOC letter 97SAP-G-0009, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, Safety Assessment for the Wolf Creek Generating Station with ZIRLOTM Fuel Assemblies," February 7, 1997.
- 6. Westinghouse to WCNOC letter 97SAP-G-0075, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, Wolf Creek Crud Deposition/Axial Offset Anomaly Safety Evaluation," September 29, 1997.
- 7. Transition core penalty applies on a cycle-specific basis for reloads utilizing both V5H (with IFMs) and STD fuel until a full core of V5H is achieved. Since a full core of V5H has been attained, the 50 degrees F transition core penalty is no longer applicable and has been removed.
- 8. Westinghouse to WCNOC letter SAP-93-701, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, 10 CFR 50.46 Notification and Reporting Information," January 25, 1993. [A PCT benefit of 2.5 degrees Fahrenheit was assessed; however, a benefit of zero (0) degrees Fahrenheit will be tracked for reporting purposes.]
- 9. Westinghouse to WCNOC letter SAP-99-148, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, 10 CFR 50.46 BART/BASH Evaluation Model Mid-Year Notification and Reporting for 1999," September 22, 1999.
- 10. This assessment is a function of analysis PCT plus certain margin allocations and as such may increase/decrease with margin allocation changes.
Attachment II to ET 02-0016 Page 3 of 4 SMALL BREAK LOCA PCT MARGIN UTILIZATION Evaluation Model: 1985 EM with NOTRUMP Fuel: 17X17 V5H w/IFM, non-IFBA, 275 psig Peaking Factor: FQ=2.50, FdH=l.65 SG Tube Plugging: 10%
Power Level: 3565 MWth Limiting transient: 3-inch Break A. ANALYSIS OF RECORD (Rerating 8/92)
Peak Cladding Temperature (PCT): 15' 100 F (1)
B. PRIOR PERMANENT ECCS MODEL ASSESSMENTS APCT = 44OF (2)
C. PLANNED PLANT CHANGE EVALUATIONS
- 1. Loose Parts APCT = 150F (3)
- 2. Cycle 10 Fuel Assembly Design Changes APCT = 1OF (6)
- 3. Reduced Feedwater Inlet Temperature APCT = 100 F (4)
- 4. Fuel Rod Crud APCT = 40F (5)
- 5. Auxiliary Feedwater Temperature Increase APCT = I60 F (8)
TOTAL PLANNED PLANT CHANGE ASSESSMENTS APCT = %6 0F D. 2001 10 CFR 50.46 MODEL ASSESSMENTS (Permanent Assessment of PCT Margin)
- 1. None APCT = OOF E. TEMPORARY ECCS MODEL ISSUES
- 1. None APCT = OoF F. OTHER MARGIN ALLOCATIONS
- 1. Cold Leg Streaming Temperature Gradient APCT = 70 F (7)
LICENSING BASIS PCT + MARGIN ALLOCATIONS PCT = 1 6370 F 0
CUMULATIVE ABSOLUTE MAGNITUDE OF PCT CHANGES Y-IAPCTI" = 35 F SINCE LAST 30-DAY REPORT (LETTER ET 99-0024)
Attachment II to ET 02-0016 Page 4 of 4 Notes/
References:
- 1. Westinghouse Topical Report WCAP-13456, "Wolf Creek Generating Station NSSS Rerating Licensing Report," October 1992.
- 2. Westinghouse to WCNOC letter SAP-00-105, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, 10 CFR 50.46 Annual Notification and Reporting for 2000," March 6, 2001.
- 3. Westinghouse to WCNOC letter SAP-90-148, "Wolf Creek Nuclear Operating Corporation, RCS Loose Parts Evaluation," April 18, 1990.
- 4. Westinghouse to WCNOC letter SAP-96-119, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, Small Break LOCA Evaluation for Reduced Feedwater Temperature," May 30, 1996.
- 5. Westinghouse to WCNOC letter 97SAP-G-0075, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, Wolf Creek Crud Deposition/Axial Offset Anomaly Safety Evaluation," September 29, 1997. (This penalty will be carried until such time it is determined to no longer apply.)
- 6. Westinghouse to WCNOC letter 97SAP-G-0009, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, Safety Assessment for the Wolf Creek Generating Station with ZIRLO TM Fuel Assemblies," February 7, 1997.
- 7. Westinghouse to WCNOC letter SAP-93-701, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, 10 CFR 50.46 Notification and Reporting Information," January 25, 1993.
- 8. Westinghouse to WCNOC letter SAP-98-138, "Wolf Creek Nuclear Operating Corporation, Wolf Creek Generating Station, Assessment of an Increase in Auxiliary Feedwater Temperature," July 23, 1998.