EPID - L-2017-LLA-0316, Proposed License Amendment Request to Revise Integrated Leak Rate Test (Type a) and Type C Test Intervals (Approved, Closed) 4 October 2017 - 25 September 2018 | |
|---|---|
Request for: - License Amendment Approved, Closed | |
Initiation
| |
| From: | |
MONTHYEARML17284A1792017-10-0404 October 2017
[table view]Title: Proposed License Amendment Request to Revise Integrated Leak Rate Test (Type a) and Type C Test Intervals ML17313A1602017-11-0909 November 2017 Title: Acceptance Review Determination Regarding License Amendment Request to Revise the Integrated Leak Rate Test (Type a) and Type C Test Intervals ML18137A3132018-05-17017 May 2018 Title: Request for Additional Information Via E-mail from R.Guzman to W.Craft Proposed License Amendment Request to Revise ILRT Type a and Type C Test Intervals ML18151A4672018-05-24024 May 2018 Title: Response to Request for Additional Information Regarding License Amendment Request to Revise Integrated Leak Rate Test (Typed a) and Type C Test Intervals ML18170A0932018-06-14014 June 2018 Title: Response to Request for Additional Information Regarding License Amendment Request to Revise Integrated Leak Rate Test (Type a) and Type C Test Intervals ML18246A0072018-09-25025 September 2018 Title: Issuance of Amendment No. 335 Regarding Revision to the Integrated Leak Rate Type a and Type C Test Intervals 2018-05-17 | |