| Event Description | The following information was received from the Texas Department of State Health Services (the Department) via email:
On March 2, 2023, a licensee notified the Department that they were unable to retract a 79.6 Ci iridium-192 source to a Delta 880 camera at a temporary job site on March 1, 2023. After an exposure, the cable was cranked in but would not lock. The technicians cranked the cable back to the collimator and called a radiation safety officer (RSO). The RSO arrived at the site and found that both technicians had extended the boundary to 1-1.5 mR/hr. He then checked the dosimetry for both technicians and found both had received about 20 mR. The RSO investigated the source and determined that it had become disconnected from the wire at the point where the wire connects to the pig tail. The source was determined to still be in the collimator. A lead blanket was then used to cover the collimator. The crank-out and guide tubes were then replaced. The end of the pig tail was slowly exposed so that the wire could be connected by hand. The source was then retracted successfully back into the camera. The RSO wore a direct reading dosimeter on his hand while doing this and reported that his hands received around 600 mR. His whole-body dosimeter measured around 400 mR. His badge has been sent in for analysis. The technicians and public did not receive additional dose from this incident. Texas Incident Number: I-9997 |
| Where | |
|---|---|
| Mistras Group Inc La Porte, Texas (NRC Region 4) | |
| License number: | L06369 |
| Organization: | Texas Dept Of State Health Services |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+35.47 h1.478 days <br />0.211 weeks <br />0.0486 months <br />) | |
| Opened: | Randall Redd 17:28 Mar 2, 2023 |
| NRC Officer: | Kerby Scales |
| Last Updated: | Mar 2, 2023 |
| 56384 - NRC Website | |
Mistras Group Inc with Agreement State | |
WEEKMONTHYEARENS 563842023-03-01T06:00:0001 March 2023 06:00:00
[Table view]Agreement State Stuck Source ENS 557432022-02-16T06:00:00016 February 2022 06:00:00 Agreement State Safety Equipment Failure ENS 550872021-01-28T23:30:00028 January 2021 23:30:00 Agreement State Disconnected Radiography Source ENS 519212016-05-11T05:00:00011 May 2016 05:00:00 Agreement State Agreement State Report - Potential Overexposure to Rad Worker ENS 509692015-04-08T05:00:0008 April 2015 05:00:00 Agreement State Agreement State Report - Radiography Camera Source Disconnect ENS 503662014-08-13T05:00:00013 August 2014 05:00:00 Agreement State Agreement State - Radiography Camera Source Would Not Retract ENS 504032014-06-03T00:30:0003 June 2014 00:30:00 Agreement State Agreement State Report - Radiography Source Failed to Retract ENS 495782013-11-22T06:00:00022 November 2013 06:00:00 Agreement State Agreement State Report - Radiography Truck Involved in Accident ENS 490442013-05-14T05:00:00014 May 2013 05:00:00 Agreement State Agreement State Report - Unable to Retract Source Into Radiography Camera ENS 486022012-12-11T06:00:00011 December 2012 06:00:00 Agreement State Agreement State Report - Radiography Camera Source Failed to Retract ENS 478792012-03-31T05:00:00031 March 2012 05:00:00 Agreement State Agreement State Report - Film Badge Indicates Radiographer Overexposure 2023-03-01T06:00:00 | |