The following information was provided by the licensee via email:
On 1/5/2023 at 1105 [MST], the control room received a call that a crane operator had operated the crane over a strap laying on the crane track. The initial inspection of the crane determined that a component of the crane had been damaged. The component was identified as a device to sweep debris from the crane rails and was not an [item relied on for safety] IROFS related component. At 0245 [MST], a Shift Manager inspected the crane and determined that the damaged component was part of IROFS27e [This IROFS is introduced for Separation Building Modules (SBM) for seismic, tornado, high wind, roof snow load, roof ponding, and site flooding due to local intense precipitation. Design features of the SBMs are to withstand loadings from these natural phenomena.] The component restrains the crane during a natural phenomena hazard. IROFS27e is an IROFS that is required to be available and reliable. An engineering analysis was initiated to determine if the crane would perform its safety function with the damaged component. Although the analysis is in progress, UUSA is reporting this event per 10 CFR 70. Appendix A (a)(4).
There were no injured personnel and no release to the environment and the plant is in a safe configuration.
This issue has been entered in UUSA's corrective action program as EV 159031.