| Title | Invalid System Actuation |
| Event Description | The following information was provided by the licensee via fax:
Auxiliary Feedwater Pump #12 actuation and isolation of the Steam Generator Blowdown for 'A', 'B' and 'C' Steam Generators. Per 10 CFR 50.73(a)(1), the telephone notification is made under 10 CFR 50.73(a)(2)(iv)(A) for an invalid actuation. On 7/28/2022 at 1705 CDT, the Unit 1 Control Room received alarm SPQD0183 'SG LO-LO LVL TRN B ACT' and actuation of the Auxiliary Feedwater Pump #12 and isolation of the Steam Generator Blowdown for 'A', 'B' and 'D' Steam Generators. This event was classified as an unplanned entry into Technical Specification Shutdown LCO equal to or less than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> 'Simple Restoration', due to the availability of CRMP. This alarm occurred several times and with each occurrence the alarm was short lived (1 second or less). Operations placed Auxiliary Feedwater Pump #12 in the Pull-To-Lock position to prevent starting of the pump with each alarm occurrence. During troubleshooting it was determined that SSPS Logic 'R' train was generating the intermittent alarm condition. A Logic board and a Safeguard Driver board were replaced which was identified as the possible cause. Operations performed applicable sections of the Logic test to ensure SSPS 'R' train operable. The event had no effects/consequences on the unit. The Logic board and Safeguard Driver board in SSPS 'R' train were both replaced as the possible causes, and therefore both boards were sent to Westinghouse to determine which board was at fault. The NRC Resident Inspector has been notified. |
| Where | |
|---|---|
| South Texas Texas (NRC Region 4) | |
| Reporting | |
| 10 CFR 50.73(a)(1), Submit an LER, Invalid Actuation | |
| Time - Person (Reporting Time:+977.02 h40.709 days <br />5.816 weeks <br />1.338 months <br />) | |
| Opened: | William Herzog 15:06 Sep 7, 2022 |
| NRC Officer: | Michael Bloodgood |
| Last Updated: | Sep 7, 2022 |
| 56094 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 56094\u003C/a\u003E - \u003Ca href=\"/South_Texas\" title=\"South Texas\"\u003ESouth Texas\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EInvalid System Actuation\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 56094 - South Texas\n","link":"","lat":30.925369444444446,"lon":-95.372575,"icon":"/w/images/9/9c/STP_Nuclear_Operating_Company_icon.png"}],"imageoverlays":null} | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 560942022-07-28T22:05:00028 July 2022 22:05:00
[Table view]10 CFR 50.73(a)(1), Submit an LER Invalid System Actuation ENS 472102011-08-28T01:30:00028 August 2011 01:30:00 10 CFR 50.73(a)(1), Submit an LER Invalid Automatic Actuation of an Emergency Diesel Generator ENS 418032005-05-17T21:02:00017 May 2005 21:02:00 10 CFR 50.73(a)(1), Submit an LER Invalid System Actuation - Auxiliary Feedwater Pump Started During Surveillance 2022-07-28T22:05:00 | |