The following information was provided by the
Illinois Emergency Management Agency (the Agency) via email:
At 0920 CDT on 4/12/2022, the Corporate Radiation Safety Officer (RSO) at Isomedix Operations, Inc. called to report a failure of the electronic brake on the irradiator vault entrance door located in Libertyville. The failure was discovered by licensee personnel at 1200 CDT on 4/11/2022. The licensee stated that operations were discontinued at this time. Following trouble shooting and diagnosis of the issue, the failure was reported to the Corporate RSO at 1830 CDT that same day. The licensee reinitiated operations after implementing temporary remedial access control measures and completing training of staff on revised procedures.
As of 1030 CDT on 4/12/2022, the licensee was advised to cease operation of the affected irradiator until further notice. Agency inspectors were dispatched on 4/12/2022 to perform a reactionary inspection. The event was called into the [NRC Headquarters Operations Officer] as required.
No personnel injuries or exposures and no adverse effects on the security system were reported.
Item Number: IL220011