| Title | Agreement State Report - Camera Source Unable to Retract | |
| Event Description | The following was reported by the Virginia Office of Radiological Health, via email:
On August 26, 2019, the Virginia Office of Radiological Health (ORH) received an incident report from the licensee, MISTRAS GROUP, Inc. The source, 66 curies of Ir-192, could not be retracted to its shielded position during radiographic work. The radiographic work involved inspecting a water tank located in an open space. The incident occurred on July 31, 2019, at about 1028 EDT at a temporary jobsite located in White Post, Virginia. The incident occurred because a magnetic stand that was utilized to support the source tube fell during an exposure, creating a kink in the source tube and preventing full retraction back to the shielded position. The radiography crew immediately established a new boundary, notified the Radiation Safety Officer (RSO) and customer, and relocated all workers outside the boundary area. A radiation survey was performed immediately at the new boundary and the measurement did not exceed 2 mR in any one hour. The site was supervised by the radiography crew until the RSO arrived at the scene and repositioned the source back to its shielding position safely. The pocket dosimeters indicated that the RSO, the radiographer, and assistant radiographer received 28 mrem, 20 mrem, and 10 mrem, respectively. In addition, the whole body dosimeters were sent to Landauer for analysis and no significant radiation exposures were reported to the RSO, Radiographer, and Assistant Radiographer. On August 28, 2019, the ORH inspector conducted a reactive inspection and it was found that the root causes of the incident were identified properly by the licensee and corrective actions, including training on procedures, on radiographic techniques, and on set up for that particular type of radiography work were discussed with the radiographer. The ORH determined that this incident is closed. The report from Virginia also stated: This incident was reported to the NRC through NMED on August 29, 2019 as if it was a 30-day notification requirement. However, the 2020 Virginia IMPEP review team discovered that it should have been classified as a 24-hour notification requirement. Accordingly, this report is being sent to correct the error. Event Report ID No: VA-19004 | |
| Where | |
|---|---|
| Virginia Rad Materials Program Midlothian, Virginia (NRC Region 1) | |
| License number: | 041-498-1 |
| Organization: | Virginia Rad Materials Program |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+10102.48 h420.937 days <br />60.134 weeks <br />13.838 months <br />) | |
| Opened: | Asfaw Fenta 12:57 Sep 24, 2020 |
| NRC Officer: | Thomas Herrity |
| Last Updated: | Sep 24, 2020 |
| 54910 - NRC Website | |
Virginia Rad Materials Program with Agreement State | ||
WEEKMONTHYEARENS 562172022-11-03T14:35:0003 November 2022 14:35:00 Agreement State Agreement State - Radioactive Source Found in Scrap Yard ENS 547742020-07-09T04:00:0009 July 2020 04:00:00 Agreement State Agreement State Report - Portable Moisture Density Gauge Damaged ENS 546822020-04-24T04:00:00024 April 2020 04:00:00 Agreement State Agreement State Report - Fixed Gauge Shutter Test Failure ENS 549102019-07-31T14:28:00031 July 2019 14:28:00 Agreement State | Agreement State Report - Camera Source Unable to Retract 2022-11-03T14:35:00 [Table view] | |