| Event Description | The following summary was initially reported by the Massachusetts Department of Public Health (DEP) and subsequently reported by the Tennessee Department of Environment and Conservation (DEC), both via phone:
The MA DEP was notified by QSA Global, Inc. that a shipping container containing 12,400 Ci of Ir-192 did not arrive at their facility as expected. The original shipment had six (6) containers but only five (5) arrived at the Burlington, MA location. The last known location of the missing container was at the [Common Carrier] facility in Memphis, TN. QSA Global was in the process of notifying local law enforcement in Tennessee. Massachusetts DPH does not believe this event to be a theft or diversion. Additionally, TN DEC was notified by [the Common Carrier] of the missing container and that a search was in progress. Notified DHS SWO, FEMA Ops Center, USDA Ops Center, HHS Ops Center, DOE Ops Center, CISA IOCC, EPA Emergency Ops Center, FDA Emergency Ops Center (email), DHS Nuclear SSA (email), FEMA NWC (email), FEMA NRCC SASC (email), and DNDO-JAC (email).
The following was reported by the Massachusetts Department of Public Health (DEP) via phone and email: At 1015 EST this morning, MA DEP was notified [by QSA Global] that the package was located by [the Common Carrier] in Memphis, TN last evening. It has been delivered to Burlington this morning, not damaged, and is in the possession of the Licensee, QSA Global, in Burlington, MA. MA DEP will continue to investigate the event. Notified R1DO (Dentel), NMSS DDD (Williams), IRDM (Grant), ILTAB (Pearson), ILTAB (email), NMSS DAY (Rivera-Capella), INES (Milligan), NMSS Event Notification (email), NMSSDHS SWO, FEMA Ops Center, USDA Ops Center, HHS Ops Center, DOE Ops Center, CISA IOCC, EPA Emergency Ops Center, FDA Emergency Ops Center (email), DHS Nuclear SSA (email), FEMA NWC (email), FEMA NRCC SASC (email), and DNDO-JAC (email). THIS MATERIAL EVENT CONTAINS A "CATEGORY 1" LEVEL OF RADIOACTIVE MATERIAL Category 1 sources, if not safely managed or securely protected would be likely to cause permanent injury to a person who handled them, or were otherwise in contact with them, for more than a few minutes. It would probably be fatal to be close to this amount of unshielded material for a period of a few minutes to an hour. These sources are typically used in practices such as radiothermal generators, irradiators and radiation teletherapy. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf |
| Where | |
|---|---|
| Ma Radiation Control Program Burlington, Massachusetts (NRC Region 1) | |
| License number: | 12-8361 |
| Organization: | Ma Radiation Control Program |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+0.18 h0.0075 days <br />0.00107 weeks <br />2.46564e-4 months <br />) | |
| Opened: | Szymon Mudrewicz 17:56 Jan 14, 2020 |
| NRC Officer: | Ossy Font |
| Last Updated: | Jan 15, 2020 |
| 54478 - NRC Website | |
Ma Radiation Control Program with Agreement State | ||
| Agreement State Report - Package Received by Licensee Exceeds Surface Radiation Dose Limits ENS 548382020-08-05T14:20:0005 August 2020 14:20:00 Agreement State Agreement State Report - Ram Packages Switched in Error ENS 548072020-07-01T04:00:0001 July 2020 04:00:00 Agreement State ENS 547592020-06-29T04:00:00029 June 2020 04:00:00 Agreement State ENS 547222020-05-20T19:52:00020 May 2020 19:52:00 Agreement State Agreement State Report - Lost Package in Transit ENS 547132020-05-14T19:04:00014 May 2020 19:04:00 Agreement State ENS 546432020-04-06T04:00:0006 April 2020 04:00:00 Agreement State Agreement State Report - Lost Material in Transit ENS 545262020-02-13T18:45:00013 February 2020 18:45:00 Agreement State ENS 545182020-02-11T19:37:00011 February 2020 19:37:00 Agreement State ENS 544782020-01-14T17:45:00014 January 2020 17:45:00 Agreement State Agreement State Report - Lost Category 1 Shipment ENS 544592019-12-31T21:45:00031 December 2019 21:45:00 Agreement State Agreement State Report - Radioactive Material Delivered to Wrong Address ENS 500702014-04-25T15:15:00025 April 2014 15:15:00 Agreement State Agreement State Report - Recovered Source ENS 405112004-02-10T05:00:00010 February 2004 05:00:00 Agreement State Load of Waste Arriving at a Waste-To-Energy Facility Set Off Radiation Monitors 2020-08-05T14:20:00 [Table view] | ||