Title | Both Source Range Instruments Found Inoperable |
Event Description | At November 9, 2019, at 0635 EST, it was discovered that both source range instrumentation channels were simultaneously inoperable; therefore, this condition is being reported as an eight-hour, non-emergency notification per 10 CFR 50.72(b)(3)(v)(A). The neutron flux monitoring system was OPERABLE during this time period.
NRC Resident Inspectors have been notified. It was determined that with one of two source range instruments out of service for planned maintenance, an operator found the other operable source range instrument out-of-calibration. Upon further investigation, the out-of-calibration instrument had a bad potentiometer with its power supply, thus rendering both instruments inoperable. |
Where | |
---|---|
Harris ![]() North Carolina (NRC Region 2) | |
Reporting | |
10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor | |
Time - Person (Reporting Time:+1.88 h0.0783 days <br />0.0112 weeks <br />0.00258 months <br />) | |
Opened: | Chuck Yarley 13:28 Nov 9, 2019 |
NRC Officer: | Brian P. Smith |
Last Updated: | Nov 9, 2019 |
54378 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 54378\u003C/a\u003E - \u003Ca href=\"/Harris\" title=\"Harris\"\u003EHarris\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EBoth Source Range Instruments Found Inoperable\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 54378 - Harris\n","link":"","lat":35.63344166666667,"lon":-78.95586666666667,"icon":"/w/images/7/75/Duke_Energy_icon.png"}],"imageoverlays":null} | |
WEEKMONTHYEARENS 543782019-11-09T11:35:0009 November 2019 11:35:00
[Table view]10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor Both Source Range Instruments Found Inoperable ENS 510112015-04-04T15:20:0004 April 2015 15:20:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Power Lost to Control Room Normal Outside Air Intake Dampers During Testing ENS 505202014-10-08T14:40:0008 October 2014 14:40:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor Potential Leak from a Pipe Could Result in Damage to Both Trains of Electrical Power Systems 2019-11-09T11:35:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_54378&oldid=2087084"