The following information was received from the State of
California via email:
On September 19, 2018, the [Radiation Safety Officer] RSO notified the [California Radiological Health Branch] that a CPN soils gauge, model MC-1DR # MD00605736 containing 10 mCi of Cs-137 and 50 mCi of Am-241/Be had been run over by construction equipment at a temporary job site in Camarillo, CA. The gauge operator had placed the gauge near his test area, but was 15 feet away when the accident occurred. After the accident, he immediately stopped all work in the area and cordoned off an area 30 feet around the damaged gauge before calling his RSO.
A radiation survey meter was available from a local radiography company who met the RSO and the gauge operator at accident site. The shaft housing the rod above the cesium source was snapped off from the gauge. The source was in the 'safe mode' during the accident and remained in the shielded area of the gauge. The gauge was able to be loaded into the shipping container for return to the permanent storage location. Radiation surveys were performed with a Bicron GM detector and no contamination was found in the area. The root cause is operator error by the gauge operator. The gauge will be disposed thru the manufacturer (CPN).
California Report No.: 5010-091918