ENS 53189
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
19:10 Jan 31, 2018 | |
| Title | Momentary Loss of Secondary Containment |
| Event Description | At 1310 hours0.0152 days <br />0.364 hours <br />0.00217 weeks <br />4.98455e-4 months <br /> [CST] on January 31, 2018, the Unit 2B fuel pool radiation monitor spiked high due to an invalid actuation which caused the U1 and U2 reactor building ventilation system to isolate, B train standby gas treatment system (SBGTS) started, and the control room ventilation system also isolated as designed. Secondary containment vacuum was lost for approximately one minute, and then subsequently returned to an acceptable level in accordance with Technical Specification 3.6.4.1, 'Secondary Containment.' As a result of this transient, secondary containment was inoperable for approximately one minute. No emergency conditions were determined to exist. Troubleshooting of the radiation monitor spike is underway.
Given the temporary loss of secondary containment vacuum, this event is reportable under 10CFR50.72(b)(3)(v)(C) as an event or condition that could have prevented the fulfillment of a safety function. The NRC Resident Inspector has been notified. |
| Where | |
|---|---|
| Quad Cities Illinois (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material | |
| Time - Person (Reporting Time:+-0.85 h-0.0354 days <br />-0.00506 weeks <br />-0.00116 months <br />) | |
| Opened: | Anthony Park 18:19 Jan 31, 2018 |
| NRC Officer: | Dong Park |
| Last Updated: | Jan 31, 2018 |
| 53189 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Quad Cities | |
WEEKMONTHYEARENS 559762022-07-04T06:30:0004 July 2022 06:30:00
[Table view]10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Both Trains of Standby Gas Treatment Inoperable ENS 531892018-01-31T19:10:00031 January 2018 19:10:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Momentary Loss of Secondary Containment ENS 525082017-01-24T16:00:00024 January 2017 16:00:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Interlock Doors Open Simultaneously ENS 516592016-01-16T02:38:00016 January 2016 02:38:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Momentary Loss of Secondary Containment ENS 516502016-01-12T19:40:00012 January 2016 19:40:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Momentary Loss of Secondary Containment ENS 511652015-06-19T06:53:00019 June 2015 06:53:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Interlock Doors Open Simultaneously ENS 510212015-04-28T14:35:00028 April 2015 14:35:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Two Secondary Containment Interlock Doors Open Simultaneously ENS 508032015-02-10T16:55:00010 February 2015 16:55:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Interlock Doors Open Simultaneously ENS 506222014-11-18T15:00:00018 November 2014 15:00:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Secondary Containment Interlock Doors Open Simultaneously ENS 501322014-05-23T02:50:00023 May 2014 02:50:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Both Hpci Secondary Containment Airlock Doors Open Simultaneously ENS 499842014-04-01T18:57:0001 April 2014 18:57:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Unit 2 Secondary Containment Interlocked Doors Opened Simultaneously ENS 498702014-03-05T01:17:0005 March 2014 01:17:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Momentary Loss of Secondary Containment ENS 497272014-01-15T13:23:00015 January 2014 13:23:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Drywell Radiation Monitor Inoperable ENS 485272012-11-20T19:21:00020 November 2012 19:21:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Drywell Radiation Monitor Inoperable ENS 483322012-09-21T19:49:00021 September 2012 19:49:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Drywell Radiation Monitor Inoperable ENS 482822012-09-06T18:14:0006 September 2012 18:14:00 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Loss of Secondary Containment Ventilation for Eight Seconds 2022-07-04T06:30:00 | |