ENS 52859
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
19:48 Mar 24, 2017 | |
| Title | Invalid Specified System Actuation During Testing |
| Event Description | This telephone notification, as allowed by 10 CFR 50.73(a)(1), is being made pursuant to 10 CFR 50.73(a)(2)(iv)(A) to describe an unplanned, invalid actuation of containment isolation valves in more than one system which occurred during the most recent refueling outage at Fermi 2. On 3/24/2017, at approximately 1548 EDT, when synchronizing an emergency diesel generator (EDG) to the grid during testing, an electrical perturbation occurred. Further investigation found that the EDG was slightly out of phase when it was attempted to be synchronized to the grid. The electrical perturbation resulted in an unexpected half-scram of Reactor Protection System (RPS) A and actuation (closure) of some containment isolation valves. The actuations were invalid as they were not initiated in response to actual plant conditions or parameters satisfying the requirements for initiation. Fermi 2 was shut down for a refueling outage at the time, and therefore, the half-scram of RPS A occurred after the safety function had already been completed. Containment isolation valves actuated (closed) in Division 1 of the Torus Water Management, Drywell Pneumatics, and Drywell Floor and Equipment Drain Sumps systems. All valves operated as expected. Since containment isolation valves in more than one system were actuated by this perturbation, this event constitutes an event or condition that resulted in manual or automatic actuation of the system listed in paragraph 10 CFR 50.73 (a)(2)(iv)(B)(2) and is reportable under 10 CFR 50.73(a)(2)(iv)(A).
The NRC Resident Inspector has been informed of this notification. |
| Where | |
|---|---|
| Fermi Michigan (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.73(a)(1), Submit an LER, Invalid Actuation | |
| Time - Person (Reporting Time:+2683.95 h111.831 days <br />15.976 weeks <br />3.676 months <br />) | |
| Opened: | Jeff Yeager 15:45 Jul 14, 2017 |
| NRC Officer: | Dong Park |
| Last Updated: | Jul 14, 2017 |
| 52859 - NRC Website
Loading map... | |
WEEKMONTHYEARENS 528592017-03-24T19:48:00024 March 2017 19:48:00
[Table view]10 CFR 50.73(a)(1), Submit an LER Invalid Specified System Actuation During Testing ENS 511282015-05-24T23:30:00024 May 2015 23:30:00 10 CFR 50.73(a)(1), Submit an LER 60-Day Optional Telephonic Notification for an Invalid Actuation of Containment Isolation Valves ENS 501122014-03-19T00:30:00019 March 2014 00:30:00 10 CFR 50.73(a)(1), Submit an LER 60-Day Optional Telephonic Notification for an Invalid Actuation of Containment Isolation Valves ENS 438502007-10-22T23:30:00022 October 2007 23:30:00 10 CFR 50.73(a)(1), Submit an LER Invalid System Actuation ENS 438402007-10-14T07:00:00014 October 2007 07:00:00 10 CFR 50.73(a)(1), Submit an LER Inadvertent Actuation of Emergency Diesel Generator ENS 424282006-02-10T16:20:00010 February 2006 16:20:00 10 CFR 50.73(a)(1), Submit an LER Invalid Specified System Actuations ENS 408992004-05-30T14:40:00030 May 2004 14:40:00 10 CFR 50.73(a)(1), Submit an LER Invalid Actuation of Containment Isolation Valves Due to Partial Loss of 120 Vac Modular Power Unit 2 Loads 2017-03-24T19:48:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_52859&oldid=81840"