ENS 50895
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
21:08 Mar 14, 2015 | |
Title | Digital Radiation Monitoring System Failed |
Event Description | At 1708 EDT on March 14, 2015, Beaver Valley Power Station (BVPS) Unit 2 determined that the Digital Radiation Monitoring System (DRMS) was not operating. This resulted in a loss of radiation monitor capability to alarm and indicate in the control room. BVPS Unit 2 DRMS was declared non-functional. Repair efforts were initiated and compensatory measures were initiated.
The radiation monitoring computer system is a stand-alone system. No cyber interference is suspected. At 2056 EDT on March 14, 2015, following initial investigation and repairs, BVPS Unit 2 emergency assessment capability was restored in conjunction with DRMS restoration. Since the BVPS Unit 2 DRMS was non-functional, this event resulted in a loss of emergency assessment capability and is reportable per 10 CFR 50.72(b)(3)(xiii). The NRC Resident Inspector has been notified. |
Where | |
---|---|
Beaver Valley Pennsylvania (NRC Region 1) | |
Reporting | |
10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
Time - Person (Reporting Time:+2.4 h0.1 days <br />0.0143 weeks <br />0.00329 months <br />) | |
Opened: | Mark Phillips 23:32 Mar 14, 2015 |
NRC Officer: | Daniel Mills |
Last Updated: | Mar 14, 2015 |
50895 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 50895\u003C/a\u003E - \u003Ca href=\"/Beaver_Valley\" title=\"Beaver Valley\"\u003EBeaver Valley\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EDigital Radiation Monitoring System Failed\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 50895 - Beaver Valley\n","link":"","lat":40.62256111111111,"lon":-80.43140277777778,"icon":""}],"imageoverlays":null} | |
Unit 2 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (100 %) |
After | Power Operation (100 %) |
Beaver Valley with 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
WEEKMONTHYEARENS 539242019-03-11T12:51:00011 March 2019 12:51:00
[Table view]10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Communication System Maintenance ENS 510642015-05-11T20:29:00011 May 2015 20:29:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Power to Digital Radiation Monitoring System ENS 508952015-03-14T21:08:00014 March 2015 21:08:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Digital Radiation Monitoring System Failed ENS 506272014-11-19T14:43:00019 November 2014 14:43:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Eal Required Gaseous Waste Effluent Radiation Monitors Removed from Service for Planned Maintenance ENS 504172014-08-29T13:32:00029 August 2014 13:32:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Digital Radiation Monitoring System Operating Intermittently ENS 497162014-01-11T21:05:00011 January 2014 21:05:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Digital Radiation Monitoring System Communication Failure ENS 491582013-06-29T16:14:00029 June 2013 16:14:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Digital Radiation Monitoring System Operating Intermittently ENS 475132011-12-05T14:45:0005 December 2011 14:45:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Unavailability of Emergency Response Data System (Erds) for Scheduled Upgrade ENS 462322010-09-07T14:43:0007 September 2010 14:43:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Plant In-Process Computer Oos for Maintenance ENS 456832010-02-06T14:28:0006 February 2010 14:28:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Siren Capability Due to Adverse Weather Conditions ENS 450232009-04-26T19:45:00026 April 2009 19:45:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Erds and Plant Computer Unavailable During Maintenance on Computer Room Cooling ENS 444872008-09-15T12:00:00015 September 2008 12:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Sirens Due to Power Outages Caused by High Winds ENS 434582007-06-29T04:14:00029 June 2007 04:14:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Radiation Monitoring Information to Erds and Spds Will Be Unavailable During Planned Upgrade to the System. ENS 430302006-12-03T23:04:0003 December 2006 23:04:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Non-Functional Safety Parameter Display System ENS 428022006-08-25T14:30:00025 August 2006 14:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Response Data System and Safety Parameter Display System Will Be Unavailable 2019-03-11T12:51:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_50895&oldid=83742"