| Title | Degraded Condition Due to Reactor Head Vessel Penetration Indications |
| Event Description | On April 18, 2014, V.C. Summer Nuclear Station (VCSNS) Unit 1 identified 3 reactor vessel head penetrations (9, 43 and 51) that did not meet the requirements of 10 CFR 50.55a(g)(6)(ii)(D) and ASME Code Case N-729-1. The station is in a refueling outage (RF21) and the plant is currently shutdown and defueled. The reactor vessel head contains a total of 66 penetrations and the volumetric inspection efforts are complete.
The indications are not through wall as indicated by volumetric and bare metal visual inspections. The penetrations will be repaired to meet the requirements of 10 CFR 50.55a prior to returning the vessel head to service. The inspection results are reportable pursuant to 10 CFR 50.72(b)(3)(ii)(A). The NRC Resident Inspector has been notified. The licensee will notify the State of South Carolina and local counties.
On April 26, 2014, V. C. Summer Station (VCSNS) Unit 1 finalized the inspections of the reactor vessel head penetrations. Confirmatory dye penetrant inspections determined that penetrations 15 and 22 also did not meet the requirements of 10CFR50.55a(g)(6)(ii)(D) and ASME Code Case N-729-1. The station is in a refueling outage (RF21) and the plant is currently shutdown and defueled. The indications are not through wall as indicated by volumetric and bare metal visual inspections. The penetrations will be repaired to meet the requirements of 10CFR50.55a prior to returning the vessel head to service. The inspection results are reportable pursuant to 10CFR50.72(b)(3)(ii)(A). The NRC Resident Inspector has been notified. The licensee will notify the State of South Carolina and local counties. Notified R2DO (McCoy). |
| Where | |
|---|---|
| Summer South Carolina (NRC Region 2) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
| Time - Person (Reporting Time:+-1.73 h-0.0721 days <br />-0.0103 weeks <br />-0.00237 months <br />) | |
| Opened: | Mike Moore 22:55 Apr 18, 2014 |
| NRC Officer: | Dong Park |
| Last Updated: | Apr 26, 2014 |
| 50044 - NRC Website
Loading map... | |
WEEKMONTHYEARENS 500442014-04-19T00:39:00019 April 2014 00:39:00
[Table view]10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Due to Reactor Head Vessel Penetration Indications ENS 484352012-10-23T23:22:00023 October 2012 23:22:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Due to Reactor Head Vessel Penetration Indications ENS 429152006-10-17T18:15:00017 October 2006 18:15:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Pressure Boundary Leakage Identified During an Outage ENS 406282004-03-30T16:29:00030 March 2004 16:29:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation, 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Automatic Reactor Trip Due to Lo-Lo Steam Generator Level ENS 402612003-10-20T11:00:00020 October 2003 11:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Rcs Through-Wall Leakage Found on Seal Injection Piping 2014-04-19T00:39:00 | |