The following information was obtained from the State of
Texas via email:
On June 5, 2013, the licensee's Radiation Safety Officer (RSO) reported to the Agency [Texas Department of Health] that on June 4, 2013, one of its radiography crews had been unable to retract the Iridium-192 source back into the SPEC 150 camera they were using in a fixed bay. The disconnect occurred after the first shot. The RSO was notified and he and two other employees performed the source retrieval. Readings from the pocket dosimeters were: RSO - 21.3 mrem; other employees performing source retrieval received 53.9 and 26.9 mrem. No member of the public received any exposure from this event. Cause of the event unknown at this time. Further information will be provided as it is obtained, per SA-300.
Radiography Camera: Spec 150, SN: 407
Source: Iridium-192, SN: UE2912
Texas Event Number: I-9089