On December 26, 2012 the licensee reported that the shutter of one of its fixed
gauges could not be closed as designed. The
gauge is a Metso Automation, Inc., Model BWM-T (Serial Number 21136049). The
gauge contains 400 mCi of
Kr-85. The
gauge is mounted on a scanning platform that traverses a paper web and is used as a sensor. The problem was noted by the on-site technician of Hoosier Technical Services Company, service provider on November 29, 2012.
Metso Automation, Inc. was contacted and the following actions were taken: The scanning platform containing the gauge was placed in the home position and removed from the process, power was removed from the equipment, and finally the old shutter mechanism was removed and replaced with a new part.
A radiation survey was performed and found to be within design parameters and regulatory limits. The Virginia Radioactive Material Program is not performing a site visit or follow-up as the shutter was repaired, all radiation levels are normal, and there was no public health or environmental concerns.
Virginia Report: VA-13-001