ENS Event | |
|---|---|
05:00 Dec 7, 2012 | |
| Title | Agreement State Report - Contamination Event |
| Event Description | The following information was obtained from the State of Tennessee via email:
On 12/10/12 at 4:30 pm EST, [the] RSO [at] Energy Solutions-Bear Creek called [the State of Tennessee] to report that last Friday, 12/7/12, a drum of DU shavings had been placed in Area 9 of the old ATG building and covered w/mineral oil. When [workers] came to work on 12/10/12, they noticed that the poly drum was completely gone, the shavings were on the floor, oil was on the floor and some of the shavings looked like ash. The poly drum had burned up and the drum/shavings and oil/ash/shavings were now on the concrete floor. There was no stack release. The stack samples were pulled and indicated less than MDA: < E-14 for U-238 and <E-15 for U- 235. Workers were not allowed to enter the area/bldg. A Hi-Volume sample was pulled with no detectable findings. Smear samples were taken with a maximum reading of 11,000 dpm. The pre-filter will be removed and counted. [Workers] are in the process of checking the temperature from a distance using a remote thermometer in order to determine if they can transfer the shavings from the floor into another oil filled container. There was no release into any drains, there was no release into the air, and there were no personnel involved/no personnel contamination. A written report is being prepared and will be sent to the Division [Tennessee Division of Radiological Health]. Tennessee Report No.: TN-12-305
The following report was received via e-mail: This is a request for event notification (EN#48577) to be retracted. The State of Tennessee Division of Radiological Health (DRH) investigation has determined, based on the information Energy Solutions (ES) supplied and the amount of DU [Depleted Uranium] lost, incident TN-12-305 did not meet the reporting requirements for the greater than five times ALI criteria. Therefore, Event Notification#48577 is being retracted. It was concluded that 126 grams of DU, or less than 37 MBq (1 mCi) of activity, is unaccounted for as a result of the oxidation incident. Energy Solutions stated that the work area sample results were 0.46 uBq/ml (1.25E-11 uCi/ml) alpha and 1.85 uBq/ml (5E-11 uCi/ml) beta with field instrument checks. Results were also less than MDA alpha and 0.2 (5.46E-12) beta with laboratory equipment checks (gamma spec). Correspondingly, the field check revealed 1.79 DAC based on 0.26 uBq/ml (7E-12 uCi/ml) DAC for Pu-239. Energy Solutions concluded that an inappropriate storage vessel was used. Corrective actions included operator training, procedural revisions, and external review by proper ES personnel. Notified R1DO (Dwyer) and FSME Events Resource. |
| Where | |
|---|---|
| Energy Solutions Oak Ridge, Tennessee (NRC Region 1) | |
| License number: | R-73006 |
| Organization: | Tennessee Div Of Rad Health |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+100.08 h4.17 days <br />0.596 weeks <br />0.137 months <br />) | |
| Opened: | Laura Turner 09:05 Dec 11, 2012 |
| NRC Officer: | Howie Crouch |
| Last Updated: | May 7, 2013 |
| 48577 - NRC Website | |
Energy Solutions with Agreement State | |
WEEKMONTHYEARENS 574402024-11-14T07:00:00014 November 2024 07:00:00
[Table view]Agreement State Exclusive Use Transport Vehicle Exceeded Exposure Rates ENS 554042021-08-10T20:00:00010 August 2021 20:00:00 Agreement State Safety Equipment Fails to Function ENS 549502020-10-12T17:15:00012 October 2020 17:15:00 Agreement State Unplanned Fire and Dose to the Public ENS 531642018-01-10T16:15:00010 January 2018 16:15:00 Agreement State Agreement State Report - Filter Replacement ENS 503192014-07-29T13:00:00029 July 2014 13:00:00 Agreement State Agreement State Report - Radioactive Material Package on Contact Radiation Reading Above Limit ENS 501962014-06-12T15:30:00012 June 2014 15:30:00 Agreement State Agreement State Report - Radiation Levels on Transportation Trailer Exceeded 200 Mr/Hr ENS 485772012-12-07T05:00:0007 December 2012 05:00:00 Agreement State Agreement State Report - Contamination Event ENS 458862010-04-30T15:31:00030 April 2010 15:31:00 Agreement State Agreement State Report - Leaking Shipping Container Identified After Shipment ENS 433062007-04-16T15:45:00016 April 2007 15:45:00 Agreement State Agreement State Report - Contaminated Shipment Exceeding Dot Regulations 2024-11-14T07:00:00 | |