At 11:30
AM December 19, 2011, the licensee's radiation safety officer provided a 24-hour telephone report notification of a shutter failure on a
gauge. The
gauge involved was an
Ohmart SH-100, serial number 70230, containing 10 mCi of
CS-137, with an assay date of Aug 1981. The shutter mechanism is a
lead block screwed to a sliding
aluminum plate. The licensee was removing the
gauge from its mounting to replace it with a different new
gauge as permitted by their license. When the licensee removed the
gauge from its mounting, the
lead block separated from the
aluminum plate. The licensee replaced the
lead shielding and secured it in place. The licensee secured the
gauge from unauthorized access and will return it to the manufacturer for disposal with other
gauges they are replacing. The licensee states that no personnel received radiation doses during this event.
Ohio Report #OH110005