The following was received via email:
On November 3, 2011, the agency [Texas Department of Health] was notified by the licensee that the shutter on an Ohmart Vega model SH-F2 containing 500 milliCurie of cesium-137 failed to close during the required maintenance check done on November 2, 2011. The gauge shutter is stuck in the open position, which is the normal operating position for the gauge and does not pose an increased exposure risk to any individual. The licensee stated that the pin attaching the operating handle to the shutter operating arm was found broken. They had not determined when the pin was broken. On November 3, 2011, the licensee determined that they could not repair the gauge. The reactor vessel the gauge is attached to is not accessed during system operation. The licensee stated that they were in the process of contacting the manufacturer for repairs or replacement of the gauge. Additional information will be provided as it is received in accordance with SA-300
Texas Report: I-8898