ENS 46895
ENS Event | |
|---|---|
04:00 Jan 1, 2005 | |
| Title | Agreement State Report - Dose Administered >20% Different from Prescribed Dose |
| Event Description | The following information was provided by the State of New York via email:
A patient was prescribed 11 mCi of Iodine-131 for hyperthyroidism but received 7 mCi. Discovered during routine NYS DOH [New York State Department of Health] inspection on 10/18/2007. DOH staff reviewed a memo from the physicist to the RSO discussing the event, but their concern was only that the expiration date on the capsule was 12/28/04 (consultation with the pharmacy after the fact indicated that it was still acceptable to us this dose). A 'left-over' capsule from the previous week (15 mCi on 12/27/2004) with activity of 7 mCi on 01/01/2005 was administered to a patient who was prescribed 11 mCi with the permission of the RSO. Additional dose was ordered and an additional 4 mCi was administered the following day so they RSO did not think it was a misadministration. Follow-up letter from RSO concluded that there was no adverse effect on the patient. Corrective actions included changing procedures and staff training on proper course of action to take in the future and incident reporting requirements. Incident is closed. New York Report Id No.: NY-11-09 A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient. |
| Where | |
|---|---|
| Not Provided Not Provided, New York (NRC Region 1) | |
| License number: | NOT PROVIDED |
| Organization: | New York State Dept. Of Health |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+56075.48 h2,336.478 days <br />333.783 weeks <br />76.812 months <br />) | |
| Opened: | Robert Snyder 14:29 May 26, 2011 |
| NRC Officer: | Howie Crouch |
| Last Updated: | May 26, 2011 |
| 46895 - NRC Website | |
Not Provided with Agreement State | |
WEEKMONTHYEARENS 550062020-11-23T04:00:00023 November 2020 04:00:00
[Table view]Agreement State Dosed Incorrect Organ ENS 543982019-11-20T18:00:00020 November 2019 18:00:00 Agreement State Agreement State Report - Iodine 125 Seed Migrated from Implant Location ENS 530172017-09-21T04:00:00021 September 2017 04:00:00 Agreement State Agreement State Report - Post Implant Loss of Iodine-125 Seed ENS 526972017-04-12T04:00:00012 April 2017 04:00:00 Agreement State Agreement State Report - Less than Intended Dose Administered to the Patient ENS 526672017-04-05T04:00:0005 April 2017 04:00:00 Agreement State Agreement State Report - Less than Prescribed Dose Administered to Patient ENS 525932017-03-04T05:00:0004 March 2017 05:00:00 Agreement State Agreement State Report - Missing Iodine 125 Calibration Sources ENS 524732016-12-29T05:00:00029 December 2016 05:00:00 Agreement State Agreement State Report - Medical Event ENS 523042016-10-17T04:00:00017 October 2016 04:00:00 Agreement State Agreement State Report - Medical Underdose ENS 519702016-05-24T04:00:00024 May 2016 04:00:00 Agreement State Agreement State Report - Medical Underdose to the Left Lobe of Liver ENS 519192015-12-02T05:00:0002 December 2015 05:00:00 Agreement State Agreement State Report - Unplanned Contamination Event ENS 513902015-09-10T04:00:00010 September 2015 04:00:00 Agreement State Agreement State Report - Medical Treatment Dose Lower than Prescribed ENS 510992015-05-27T05:00:00027 May 2015 05:00:00 Agreement State Agreement State Report - Lost Iodine-125 Medical Seeds ENS 510372015-04-30T05:00:00030 April 2015 05:00:00 Agreement State Agreement State Report - Ruptured Iodine Seed During Removal ENS 508102015-01-12T05:00:00012 January 2015 05:00:00 Agreement State Agreement State Report - Medical Misadministration During Cancer Treatment ENS 434962007-07-11T06:00:00011 July 2007 06:00:00 Agreement State Agreement State Report - Moisture Gauge Source Disconnected from Cable ENS 433012007-03-07T04:00:0007 March 2007 04:00:00 Agreement State Agreement State Report - Medical Event ENS 468952005-01-01T04:00:0001 January 2005 04:00:00 Agreement State Agreement State Report - Dose Administered >20% Different from Prescribed Dose 2020-11-23T04:00:00 | |