14:30 Apr 27, 2011 | |
| Title | Loss of Emergency Sirens Due to Loss of Electric Power |
| Event Description | At approximately 1030 EDT on April 27, 2011, [Sequoyah Nuclear Plant] received notification from TVAs Operations Duty Specialist that >30% of offsite sirens are not functional resulting in a 'major loss' of offsite [automatic] public notification [capabilities]. The loss of offsite sirens is due to loss of electrical power caused by severe thunderstorms and high winds in the area. Thirty five sirens are not functioning (32 sirens are considered 30%). Efforts are in place to restore offsite sirens to service.
At 1044 EDT on April 27, 2011, power was restored to 2 offsite sirens leaving 33 offsite sirens not functional. At 1050 EDT on April 27, 2011, TVA's Operations Duty Specialist made a notification to Tennessee Emergency Management Agency (TEMA) and Hamilton County Emergency Response. The licensee has notified the NRC Resident Inspector.
Sequoyah Nuclear Plant reported that 28 of 108 sirens are not functional (26%) which is below the 'major loss' of offsite automatic public notification capabilities threshold. The licensee has notified the Tennessee Emergency Management Agency (TEMA) and Hamilton County Emergency Response. The licensee will notify the NRC Resident Inspector. Notified R2DO (Seymour). |
| Where | |
|---|---|
| Sequoyah Tennessee (NRC Region 2) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
| Time - Person (Reporting Time:+-1.4 h-0.0583 days <br />-0.00833 weeks <br />-0.00192 months <br />) | |
| Opened: | Tim Reed 13:06 Apr 27, 2011 |
| NRC Officer: | Howie Crouch |
| Last Updated: | Apr 29, 2011 |
| 46790 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (92 %) |
| After | Power Operation (92 %) |
Sequoyah | ||
WEEKMONTHYEARENS 565922023-06-27T12:31:00027 June 2023 12:31:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 558672022-04-29T03:38:00029 April 2022 03:38:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Assessment Capability ENS 557422022-02-16T16:28:00016 February 2022 16:28:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Offsite Communication Capability ENS 549772020-11-01T09:56:0001 November 2020 09:56:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Seismic Assessment Instrumentation ENS 549182020-09-28T15:43:00028 September 2020 15:43:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release | Offsite Notification - Oil Spill ENS 543802019-11-12T12:00:00012 November 2019 12:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Operations Facility Out of Service ENS 542762019-09-13T09:27:00013 September 2019 09:27:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness En Revision Imported Date 9/17/2019 ENS 537542018-11-26T05:00:00026 November 2018 05:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared for Excessive Smoke in Containment ENS 536802018-10-21T04:00:00021 October 2018 04:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Death of Employee on Site ENS 532702018-03-19T04:30:00019 March 2018 04:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Two Contractors Injured by Arc Flash ENS 524262016-12-13T19:10:00013 December 2016 19:10:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification - Water Containing Tritium Spilled Into Storm Drain ENS 521722016-08-11T14:15:00011 August 2016 14:15:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Control Room Emergency Ventilation System Declared Inoperable ENS 508532015-02-27T18:05:00027 February 2015 18:05:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Notification System and Health Physics Network Telephone Lines Out of Service ENS 507572015-01-23T16:50:00023 January 2015 16:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notifications Due to Oil Sheen on Intake Bay ENS 505812014-10-30T16:20:00030 October 2014 16:20:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Regarding Boone Dam Stability Issues ENS 497382014-01-17T19:00:00017 January 2014 19:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Fuel Oil Found During Core Drilling ENS 480742012-07-06T14:12:0006 July 2012 14:12:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Loss of 21 Offsite Sirens Due to Inclement Weather ENS 479592012-05-24T19:41:00024 May 2012 19:41:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Oil Sheen on the River ENS 479222012-05-14T14:24:00014 May 2012 14:24:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Oil Sheen Observed on Diffuser Pond ENS 475342011-12-19T21:44:00019 December 2011 21:44:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Tritium Levels Exceeding Threshold for Drinking Water ENS 472562011-09-12T17:05:00012 September 2011 17:05:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to the Tennessee Department of Environment and Conservation (Tdec) ENS 470452011-07-13T04:23:00013 July 2011 04:23:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Overflow of Condenser Circulating Water ENS 467902011-04-27T14:30:00027 April 2011 14:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Sirens Due to Loss of Electric Power ENS 461952010-08-21T19:09:00021 August 2010 19:09:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Notification of State Agencies Due Leak of a Water Treatment Chemical ENS 456682010-01-31T15:42:00031 January 2010 15:42:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Tema Notified of a Loss of Emergency Sirens ENS 453952009-09-30T19:21:00030 September 2009 19:21:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to Various Government Agencies ENS 453702009-09-20T22:26:00020 September 2009 22:26:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Major Loss of Communications Due to Lightning Strike ENS 453532009-09-16T16:20:00016 September 2009 16:20:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Made After Discovery of an Oil Sheen ENS 451722009-06-29T15:34:00029 June 2009 15:34:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Possible Release of Fuel Oil to the Environment ENS 450642009-05-13T19:05:00013 May 2009 19:05:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Track Hoe Slid Into Intake Forebay ENS 435432007-08-01T16:00:0001 August 2007 16:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness 77 Out of 108 Prompt Notification System Sirens Failed Their Monthly Test ENS 428572006-09-24T08:30:00024 September 2006 08:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Notification System and Commercial Telephone Line Problems ENS 406552004-04-08T12:45:0008 April 2004 12:45:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Off Site Notification 2023-06-27T12:31:00 [Table view] | |