A
service water pump failed during operation on 9/29/2009. Upon disassembly it was detected that a shaft
coupling installed on a repaired
service water pump failed while in service. The failed
coupling was replaced with a new
coupling of a different heat code. According to the manufacturer, the threaded
coupling design was only supplied for Palisades.
- * * UPDATE FROM SESHA GIRI TO PETE SNYDER AT 1529 ON 2/22/10 * * *
HydroAire conducted a root cause analysis on the issue. They and their heat treat vendor, BodyCote, reviewed all of their safety related work records for the past three years and monitored heat treating of recent orders.
Records showed that this anomaly occurred only on one piece and it is a random isolated incident."
The vendor believes that corrective actions that they and BodyCote have taken "should remove concerns in the future heat treatments and past review of records confirms adequacy of the heat treat at least for the past three years.
Notified R3DO (Stone) and Part 21 Group via email.