| Title | Inadvertent Actuation of One Automatic Notification System Siren |
| Event Description | At approximately 1242 on April 20, 2009, three New Jersey Emergency Planning Zone (EPZ) Alert Notification System sirens went into AC power failure. This caused an automatic swap of the power supply from an AC source to a back up DC battery source. When this auto swap occurred, the Salem County 9-1-1 Center received an alarm which the dispatcher acknowledged. Sirens 127 and 114 were successfully acknowledged but when the dispatcher went to acknowledge Siren 128 he inadvertently selected 'alert with report' at 12:50:34 which when selected, initiated the siren. An ANS Services technician immediately received notification of the siren system actuation and called the Salem County 9-1-1 Center to provide direction to cancel the actuation. The siren actuation was cancelled at 12:52:21. Salem County officials notified the Lower Alloways Creek (LAC) Public Safety director and the New Jersey State Police (NJSP). The NJSP was notifying the NJ Regional Operation Intelligence Center (ROIC), LAC Police, and making a courtesy call to the LAC elementary school which is located in the vicinity of the siren. This event is being reported to NRC in accordance with the requirements of 10CFR50.72(b)(2)(xi).
The licensee has notified the NRC Resident Inspector. |
| Where | |
|---|---|
| Salem New Jersey (NRC Region 1) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release | |
| Time - Person (Reporting Time:+-1.12 h-0.0467 days <br />-0.00667 weeks <br />-0.00153 months <br />) | |
| Opened: | John Osborne 15:43 Apr 20, 2009 |
| NRC Officer: | Howie Crouch |
| Last Updated: | Apr 20, 2009 |
| 45002 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 547162020-05-15T13:47:00015 May 2020 13:47:00
[Table view]10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to a Hydraulic Oil Spill ENS 536912018-10-23T04:00:00023 October 2018 04:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Notification of Environmental Report to Another Government Agency ENS 522452016-09-16T13:13:00016 September 2016 13:13:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Hydraulic Fluid (Fish Oil) Spill ENS 501142014-05-13T21:05:00013 May 2014 21:05:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Five Gallons of Diesel Fuel Spilled Onsite Requiring State Notification ENS 500392014-04-16T13:08:00016 April 2014 13:08:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Minor Hydraulic Oil Spill in the Delaware River ENS 480932012-07-11T15:57:00011 July 2012 15:57:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Discovery of Ammonia Found in Groundwater ENS 479282012-05-17T02:10:00017 May 2012 02:10:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release State Notification of Potential Chlorine Discharge to the Delaware River ENS 477722012-03-26T19:30:00026 March 2012 19:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Sewage Lift Station Overflow ENS 475952012-01-14T22:55:00014 January 2012 22:55:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to a Chlorinated Water Discharge ENS 471602011-08-17T00:10:00017 August 2011 00:10:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Chlorine Spill ENS 466102011-02-11T18:12:00011 February 2011 18:12:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Hydrazine Spill Onsite ENS 464832010-12-15T18:20:00015 December 2010 18:20:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of an Ammonia Spill Into the Delaware River ENS 458522010-04-18T11:50:00018 April 2010 11:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Fatality During Medical Transport ENS 458472010-04-16T20:49:00016 April 2010 20:49:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Discovery of Diesel Fuel Oil in a Monitoring Well ENS 457922010-03-26T02:39:00026 March 2010 02:39:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Piping Leak That Cannot Be Cleaned Up within 24 Hours ENS 457602010-03-11T22:45:00011 March 2010 22:45:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Press Release Concerning a Former Plant Employee ENS 450022009-04-20T16:50:00020 April 2009 16:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertent Actuation of One Automatic Notification System Siren ENS 446372008-11-07T14:55:0007 November 2008 14:55:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Discharge of Biodegradable Oil Into Intake Bay ENS 426592006-06-21T21:10:00021 June 2006 21:10:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Chemical Spill to the Delaware River ENS 425752006-05-15T03:20:00015 May 2006 03:20:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Sodium Hypochlorite Leak Into the Delaware River ENS 425632006-05-10T06:15:00010 May 2006 06:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Notification of Offsite Ammonia and Hydrazine Release ENS 419422005-08-23T19:45:00023 August 2005 19:45:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to State of New Jersey Due to Chemical Spill ENS 416792005-05-07T15:50:0007 May 2005 15:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notifications Due to Hydrazine Release ENS 415812005-04-09T00:09:0009 April 2005 00:09:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of Water Discharge Containing Hydrazine ENS 414892005-03-14T15:17:00014 March 2005 15:17:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of Sodium Hypochlorite Spill ENS 413652005-02-02T15:34:0002 February 2005 15:34:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notifications Due to Oil Sheen on the Delaware River ENS 412402004-12-03T00:30:0003 December 2004 00:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Press Release Concerning the Planned Shutdown of the Salem Units Due to an Oil Spill ENS 409152004-08-02T19:58:0002 August 2004 19:58:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Fuel Leak- Offsite Notification to New Jersey Department of Environmental Protection. ENS 406072004-03-23T19:32:00023 March 2004 19:32:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notifications Made Due to an Ethylene Glycol Spill from Underground Piping ENS 405452004-02-25T16:15:00025 February 2004 16:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to New Jersey Department of Environmental Protection ENS 401152003-08-29T11:20:00029 August 2003 11:20:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Discharge of Waste Water Containing Hydrazine 2020-05-15T13:47:00 | |