| Title | Agreement State Report - Source Disconnected from Radiography Camera |
| Event Description | The following information was received from the State of Minnesota via email:
Licensee was performing radiography on steam pipes in a bunker under the road (temporary jobsite). The bunker is accessed by two manholes in the street. At approximately 10:40 a.m. on 8/21/08 the licensee had a disconnect. The assistant under the supervision of the radiographer was cranking the source in, but did not feel it lock into place. The radiographer used the survey meter while the assistant cranked in and out. The readings on the survey meter did not change so they knew they had a disconnect and called the RSO. The RSO was notified at approximately 11:00 a.m. The RSO and another employee (former RSO) went to the scene. When they arrived onsite the readings at the manhole entrances were 80 mR/hr and 150 mR/hr, a couple of feet to the sides was background. The radiographer had roped off the area around the manhole entrances and the roped area was maintained until the RSO arrived on-site. The RSO, former RSO, and radiographer used telescopic poles to manipulate the camera, and guide tube into a position where the could lower bags filled with lead shot to shield the source. They were then able to enter the bunker and use a 'fishing' cable run through the camera and guide tube to grab the source. They exited the bunker and pulled the 'fishing' cable back until the source locked into the camera. The RSO and other employee were wearing dosimeters, direct reading dosimeters (DRDs), and alarming rate meters. At the end of the retrieval the RSO and former RSO had reading on there DRDs of 30 - 35 mR each. The radiographer had a reading on his DRD of 25 mR. In looking at the pig tail after the incident, the licensee thinks there is a faulty pig tail connection. The connection between the drive cable and pig tail needed to be forced to get connected, but once connected 'felt sloppy.' The licensee contacted the manufacturer and will be returning the source and cables to the manufacturer for investigation. Camera: QSA 660B Source: QSA 424-9, Ir-192, 142 Ci |
| Where | |
|---|---|
| Braun Minnesota (NRC Region 3) | |
| License number: | 1082-102-27 |
| Organization: | Minnesota Department Of Health |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+-2.83 h-0.118 days <br />-0.0168 weeks <br />-0.00388 months <br />) | |
| Opened: | Brandon Juran 14:10 Aug 22, 2008 |
| NRC Officer: | Vince Klco |
| Last Updated: | Aug 22, 2008 |
| 44434 - NRC Website
Loading map... | |
Braun Intertec Corporation with Agreement State | |
WEEKMONTHYEARENS 579642025-10-02T19:50:0002 October 2025 19:50:00
[Table view]Agreement State Damaged Moisture Density Gauge ENS 571332024-05-17T00:00:00017 May 2024 00:00:00 Agreement State Stuck Source ENS 537912018-12-12T06:00:00012 December 2018 06:00:00 Agreement State Agreement State Report - Radiography Guide Tube Kinked with Source Exposed ENS 485822012-12-10T16:43:00010 December 2012 16:43:00 Agreement State Agreement State - Source Disconnected from Radiography Camera ENS 477502012-03-15T20:30:00015 March 2012 20:30:00 Agreement State Agreement State Report - Radiography Camera Stuck Source ENS 444342008-08-22T17:00:00022 August 2008 17:00:00 Agreement State Agreement State Report - Source Disconnected from Radiography Camera 2025-10-02T19:50:00 | |