ENS 44264
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
05:00 Jun 3, 2008 | |
| Title | Agreement State Report - Radiopharmaceuticals Delivery Vehicle Accident |
| Event Description | The State provided the following information via facsimile:
On June 3, 2008, a Cardinal Health delivery vehicle carrying nuclear medicine doses was involved in a vehicle accident. Some of the ammo boxes containing the syringe pigs opened, however the syringe pigs remained intact. No radioactive material was spilled or leaked during this accident. Louisiana Report: LA0800012 |
| Where | |
|---|---|
| Cardinal Health New Orleans, Louisiana (NRC Region 4) | |
| License number: | LA-3385-L01 |
| Organization: | Louisiana Radiation Protection Div |
| Reporting | |
| Agreement State | |
| Time - Person (Reporting Time:+32.6 h1.358 days <br />0.194 weeks <br />0.0447 months <br />) | |
| Opened: | Richard Penrod 13:36 Jun 4, 2008 |
| NRC Officer: | Mark Abramovitz |
| Last Updated: | Jun 4, 2008 |
| 44264 - NRC Website | |
Cardinal Health with Agreement State | |
WEEKMONTHYEARENS 578142025-07-16T04:00:00016 July 2025 04:00:00
[Table view]Agreement State Loss of Control of Radioactive Material ENS 573482024-09-27T09:00:00027 September 2024 09:00:00 Agreement State Agreement State - Courier Vehicle Accident ENS 569692024-02-05T14:00:0005 February 2024 14:00:00 Agreement State Lost Source ENS 566272023-07-10T04:00:00010 July 2023 04:00:00 Agreement State Eluate Exceeded Mo-99 Limit ENS 558812022-05-05T14:45:0005 May 2022 14:45:00 Agreement State Transportation Event ENS 543572019-10-29T08:15:00029 October 2019 08:15:00 Agreement State Agreement State Report - Stolen Sources ENS 542252019-08-14T17:00:00014 August 2019 17:00:00 Agreement State Agreement State Report - Vehicle Accident During Radiopharmaceutical Transport ENS 539312019-02-26T04:00:00026 February 2019 04:00:00 Agreement State Agreement State Report - Mo-99/Tc-99 Breakthrough Limit Exceeded. ENS 533592018-04-23T04:00:00023 April 2018 04:00:00 Agreement State Agreement State Report - Stolen Technicium-99 ENS 526592017-03-22T04:00:00022 March 2017 04:00:00 Agreement State Agreement State Report - Package Lost During Shipment ENS 526172017-03-17T11:00:00017 March 2017 11:00:00 Agreement State Agreement State Report - Transportation Accident Damaging Licensed Material ENS 519712016-06-01T05:00:0001 June 2016 05:00:00 Agreement State Agreement State Report - Two Radioactive Materials Packages Not Located After Carrier Accident ENS 509202015-03-01T04:00:0001 March 2015 04:00:00 Agreement State Agreement State Report - Radiation Technician Potential Overexposure ENS 504812014-08-27T07:00:00027 August 2014 07:00:00 Agreement State Agreement State Report - Radioactive Material Release Exceeding Emission Limit ENS 496752013-12-06T05:00:0006 December 2013 05:00:00 Agreement State Agreement State Report - Licensed Material Recovered at a Landfill ENS 494022013-09-23T04:00:00023 September 2013 04:00:00 Agreement State Agreement State Report - Radiopharmaceutical Worker Received >50 Rem to Both Hands ENS 475602011-12-21T08:00:00021 December 2011 08:00:00 Agreement State Agreement State Report - Iodine-125 Brachytherapy Seed Missing from Transportation Package ENS 465662010-12-28T06:00:00028 December 2010 06:00:00 Agreement State Agreement State Report - Transportation Accident Involving Radiopharmaceuticals ENS 464512010-12-02T11:20:0002 December 2010 11:20:00 Agreement State Agreement State Report - Employee Contaminations During Cyclotron Operation ENS 453422009-09-11T09:30:00011 September 2009 09:30:00 Agreement State Agreement State Report - Contaminated Pharmacy Shipment Package ENS 453632009-07-21T04:00:00021 July 2009 04:00:00 Agreement State Agreement State - Potential Extremity Overexposure ENS 443072008-06-13T08:00:00013 June 2008 08:00:00 Agreement State Agreement State Report Involving a Vehicle Transporting Radioactive Material ENS 442642008-06-03T05:00:0003 June 2008 05:00:00 Agreement State Agreement State Report - Radiopharmaceuticals Delivery Vehicle Accident ENS 441362008-04-09T12:00:0009 April 2008 12:00:00 Agreement State Agreement State - Mississippi - Traffic Accident Involving Truck Carrying Tc-99M ENS 441392008-03-19T04:00:00019 March 2008 04:00:00 Agreement State Agreement State - Florida - Missing Dose of Tc-99M ENS 438412007-11-19T15:13:00019 November 2007 15:13:00 Agreement State Agreement State Report - Dose to Wrong Organs ENS 437312007-09-24T05:00:00024 September 2007 05:00:00 Agreement State Agreement State Report Involving an Improper Injection ENS 434322007-05-16T05:00:00016 May 2007 05:00:00 Agreement State Louisiana Agreement State Report - Medical Event Due to Dispensing Error ENS 432012007-02-14T06:00:00014 February 2007 06:00:00 Agreement State Agreement State Report - Dispensing Error for Thallium -201 Dose ENS 429992006-11-16T06:00:00016 November 2006 06:00:00 Agreement State Agreement State - Stolen Truck Containing Radiopharmiceuticals ENS 428582006-09-22T11:00:00022 September 2006 11:00:00 Agreement State Agreement State Report - Traffic Accident Involving a Truck Carrying Radioactive Material ENS 426242006-05-22T05:00:00022 May 2006 05:00:00 Agreement State Agreement State Report - Unsecured Delivery of Radioactive Material ENS 424412006-03-22T08:00:00022 March 2006 08:00:00 Agreement State Agreement State Report - Radiation Exposure ENS 424182006-03-05T06:00:0005 March 2006 06:00:00 Agreement State Agreement State Report - Patient Received Improper Medical Dose ENS 422732006-01-18T06:00:00018 January 2006 06:00:00 Agreement State Agreement State Report of an Extremity Exposure Greater than Limit ENS 422362005-12-29T16:45:00029 December 2005 16:45:00 Agreement State Agreement State Report - Transportation Accident Involving Used Technetium 99M Syringes ENS 422232005-12-22T12:30:00022 December 2005 12:30:00 Agreement State Agreement State Report of Traffic Accident Involving Radioactive Material ENS 418402005-06-26T21:20:00026 June 2005 21:20:00 Agreement State Agreement State - Medical Sources Stolen ENS 414692005-03-08T13:40:0008 March 2005 13:40:00 Agreement State Agreement State Report - Truck Containing Radiopharmaceuticals Stolen in Massachusetts ENS 413512005-01-20T17:00:00020 January 2005 17:00:00 Agreement State Agreement State Report Involving a Pharmacy Spill of Samarium-153 ENS 413062005-01-01T10:00:0001 January 2005 10:00:00 Agreement State Agreement State Report of Truck Crash Resulting in Minor Contamination and Loss of Radiopharmaceutical Vials ENS 412712004-10-25T20:00:00025 October 2004 20:00:00 Agreement State Agreement State Medical Event ENS 409362004-08-09T13:30:0009 August 2004 13:30:00 Agreement State Spill of I-131 Resulting in Contamination ENS 418332004-05-02T04:00:0002 May 2004 04:00:00 Agreement State Agreement State Report Involving a Potential Extremity Overexposure ENS 408482004-02-27T05:00:00027 February 2004 05:00:00 Agreement State Lousiana Agreement State Report - Medical Event ENS 405532004-02-26T21:00:00026 February 2004 21:00:00 Agreement State Agreement State Reports Spill at Nuclear Pharmacy 2025-07-16T04:00:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_44264&oldid=1184018"