ENS 43813
ENS Event | |
|---|---|
22:24 Nov 28, 2007 | |
| Title | |
| Event Description | This communication is being made in accordance with 50.72(b)(2)(xi) and the Nuclear Energy Institute (NEI) Industry Ground Water Protection Initiative. Millstone Power Station and other nuclear power stations across the country are participating in this voluntary initiative to develop and improve ground water protection programs at nuclear power stations. This communication provides notification of preliminary sample analysis of water that seeped into the foundation drain sump outside of the Millstone Unit 3 engineered safety features building. This water is pumped to the station yard drain system and discharged to Long Island Sound via a permitted and monitored pathway for the station. Tritium was detected at a concentration of approximately 34,000 picoCuries per liter in a sample of the water from the sump. The NEI reporting threshold for tritium concentrations is 20,000 picoCuries per liter.
Investigation into the source of the tritium is underway and at the present time the source has not been determined. The presence of tritium at this location does not present a health hazard to plant employees or the general public. Samples from several wells closest to the affected sump show no detectable concentrations of tritium. Additional sampling is underway. Based on the known hydrology of the site, public drinking water supplies are not affected. The licensee notified the following agencies: CT Department of Environmental Protection, CT Department of Emergency Management and Homeland Security, CT Department of Public Utilities Control, The Town of Waterford, and The Town of East Lyme. The licensee performed pump maintenance in the sump. At the same time, they performed samples of the water in the sump and found the high tritium concentration in the samples taken. The licensee notified the NRC Resident Inspector. |
| Where | |
|---|---|
| Millstone Connecticut (NRC Region 1) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release | |
| Time - Person (Reporting Time:+18.12 h0.755 days <br />0.108 weeks <br />0.0248 months <br />) | |
| Opened: | Gary Closius 16:31 Nov 29, 2007 |
| NRC Officer: | Joe O'Hara |
| Last Updated: | Nov 29, 2007 |
| 43813 - NRC Website
Loading map... | |
Unit 3 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 535332018-08-02T04:00:0002 August 2018 04:00:00
[Table view]10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Release of Possible Tritium Bearing Water ENS 534282018-05-27T02:01:00027 May 2018 02:01:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Spurious Siren Actuation ENS 529482017-09-06T15:15:0006 September 2017 15:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Potential Release of Tritium Bearing Water and Secondary Chemicals Into the Protected Area ENS 516322016-01-03T04:05:0003 January 2016 04:05:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of Fish Kill ENS 513512015-08-26T23:20:00026 August 2015 23:20:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Tree Branch Fell on Amtrak Power Line and Caused Brush Fire ENS 492992013-08-22T18:50:00022 August 2013 18:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of a Fatality at Millstone Unit 3 ENS 482792012-09-05T17:25:0005 September 2012 17:25:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of Small Oil Spill ENS 451662009-06-26T17:00:00026 June 2009 17:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Onsite Fatality ENS 449782009-04-08T18:55:0008 April 2009 18:55:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to the State of Connecticut Due to Onsite Fatality ENS 438132007-11-28T22:24:00028 November 2007 22:24:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of High Tritium Levels in Sump ENS 432642007-03-29T13:00:00029 March 2007 13:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to Local Law Enforcement ENS 422612006-01-16T22:03:00016 January 2006 22:03:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Small Fire Occurred in Security Department Storage Area. ENS 403212003-11-13T22:15:00013 November 2003 22:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Licensee Called the Waterford, Ct. Fire Department to Assist in Extingushing a Fire Outside the Protected Area 2018-08-02T04:00:00 | |