This afternoon [at 1330
CST, the State of Illinois] received a call from the [Deleted], the Radiation Safety Officer [RSO] for Bard
Brachytherapy located in Carol Stream, IL. The
RSO advised that a package of fifty one,
I-125 seeds with a total activity of 38 milliCuries, had been returned to them from a client that had abnormal radiation levels associated with the package. Surface readings showed 600 mr/hr and readings at 1 meter showed 1.4 mr/hr. Their investigation quickly showed that all sources identified in the shipping papers were accounted for. However, the lid to the pig which shielded the contents had become askew during transit due to failure to secure it properly resulting in the elevated readings. The vial within the leaded container was intact with no signs of external radioactive contamination or loss of integrity. The
RSO promptly notified the shipper,
Virginia Mason Medical Center of Seattle,
Washington as well as the courier's (Federal Express) radiation safety officer. There is no reason to suspect that there were any
overexposures to transportation personnel as a result of the event considering the low level gamma radiation associated with
I-125. This event has no media attention associated with it at this time, nor are there any security concerns associated with it. Given the improper preparation of the package by the shipper, no further action is expected from Bard
Brachytherapy at this time save for filing the appropriate written report.
IL Event No: IL070058
See also
EN#43778,
Washington State Agreement State report.