At 1710 EDT on 08/14/07, a
Troxler moisture density gauge, model 3430, serial number 36254, was in use at a construction worksite on
VA Route 460. A large piece of construction equipment was backing up and while the
gauge technician attempted to get the vehicle driver's attention, the vehicle ran over the
Troxler gauge. The 8 millicurie
Cs-137 source was extended and after the damage could only be retracted to within 4 inches of the
gauge case. The technician kept the extended source in the ground and controlled access to the area. The
gauge technician called the NRC Operations Center for assistance.
R1DO (Paul Krohn) and FSME EO (Holonich) were notified and briefed by the licensee technician on what assistance was required. During the conference call the RSO was notified and the company was dispatching personnel to the scene to assist.
- * * UPDATE PROVIDED BY CURTIS HOWELL TO JEFF ROTTON AT 1953 EDT ON 08/14/07 * * *
The licensee was able to retract the source and close the shutter door. No significant personnel exposure was received. The area has been opened for unrestricted access.
Notified R1DO (Krohn) and
FSME EO (Holonich).