ENS 43420
ENS Event | |
|---|---|
12:00 Jun 13, 2007 | |
| Title | Notifications Made for Detection of Tritium in Onsite Water Samples |
| Event Description | On May 8, 2007, measurable levels of tritium were identified in two manholes (i.e., MW-5 and MW-6) that route cable to a nearby meteorological tower. The manholes are located within the boundaries of the site owner controlled area. The manholes are also in close proximity to the Storm Drain Stabilization Pond (SDSP). The SDSP is an area of approximately 64 acres consisting of a non-lined perimeter dike of approximately 12 to 15 feet in height. The site storm drain system collects in the storm drain collector basin and is then pumped to the SDSP. The storm drain collector basin receives overflow from the Turbine Building air-wash system, which contains very small amounts of tritium. By plant design, the tritiated water of the SDSP is then pumped into the intake canal during monitored, controlled releases, compliant with all permits and regulations.
As a result of ongoing investigations to determine the source and potential migration path of the tritium, an increased environmental sampling program was initiated. On June 13, 2007, tritium levels in excess of Nuclear Energy Institute (NEI) voluntary reporting criteria were confirmed to be present in new onsite shallow groundwater wells. Immediate corrective actions taken were to perform additional sampling of areas surrounding the stabilization pond and [to reconfigure] the Turbine Building air-wash system. The reconfiguration of the turbine building airwash system will be done to eliminate the designed pathway of water to the storm drain collection basin and to the storm drain stabilization pond. Additional corrective actions include installation of additional monitoring wells at various locations to determine groundwater flow and checking for the presence of tritium. There is no indication that tritium has migrated into drinking water sources and all offsite monitoring has resulted in non-detectable levels of tritium. It is believed that the likely source of the tritiated water is seepage from the SDSP. The following agencies will be updated on the status of the onsite tritium samples and informed of the pending press release: State Officials, City of Southport, Brunswick County, NEI, INPO, and ANI. The Licensee notified the NRC Resident inspector. |
| Where | |
|---|---|
| Brunswick North Carolina (NRC Region 2) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release | |
| Time - Person (Reporting Time:+-0.2 h-0.00833 days <br />-0.00119 weeks <br />-2.7396e-4 months <br />) | |
| Opened: | Lee Grzeck 11:48 Jun 13, 2007 |
| NRC Officer: | Pete Snyder |
| Last Updated: | Jun 13, 2007 |
| 43420 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 547332020-06-02T23:05:0002 June 2020 23:05:00
[Table view]10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to the Department of Transportation ENS 543222019-10-10T15:22:00010 October 2019 15:22:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Environmental Report to Another Government Agency ENS 534132018-05-21T04:00:00021 May 2018 04:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Regarding Malfunction of Emergency Notification Siren ENS 534062018-05-17T14:45:00017 May 2018 14:45:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Emergency Notification Siren Malfunctioning ENS 528452017-07-10T20:02:00010 July 2017 20:02:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Contract Employee Fatality ENS 520802016-07-11T21:45:00011 July 2016 21:45:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Non-Work Related On-Site Contractor Fatality ENS 518482016-04-05T13:50:0005 April 2016 13:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Employee Fatality ENS 507532015-01-23T11:13:00023 January 2015 11:13:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Non-Work Related On-Site Contractor Fatality ENS 499932014-04-03T14:06:0003 April 2014 14:06:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Oil Spill on Site ENS 487612013-02-16T19:03:00016 February 2013 19:03:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Onsite Contractor Fatality ENS 482192012-08-21T23:30:00021 August 2012 23:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Damaged Packaging Containing Radioactive Material ENS 464732010-12-10T04:04:00010 December 2010 04:04:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification - Agencies Notified of Onsite Tritium Leak ENS 448852009-03-02T14:15:0002 March 2009 14:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Onsite Fatality ENS 440412008-03-07T15:30:0007 March 2008 15:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Tritium in Onsite Water Samples ENS 436952007-10-05T22:47:0005 October 2007 22:47:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Sodium Hypochlorite Spill While Offloading a Tanker Truck ENS 434202007-06-13T12:00:00013 June 2007 12:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Notifications Made for Detection of Tritium in Onsite Water Samples ENS 409582004-08-15T17:22:00015 August 2004 17:22:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Made Due to Inadvertent Emergency Siren Actuation ENS 408022004-06-10T06:05:00010 June 2004 06:05:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Made Due to Inadvertent Emergency Siren Actuation 2020-06-02T23:05:00 | |