Notification of shutdown required by the Technical Specifications per 10CFR50.72(b)(2)(i).
Arkansas Nuclear One Unit 2 is shut down in Mode 3 (Hot Standby) due to Control Element Assembly misalignment as required by
Technical Specification 3.1.3.1.d (All
CEAs shall be
OPERABLE with each
CEA of a given group positioned within 7 inches, indicated position, of all other
CEAs in its group).
CEA #35 dropped to the bottom of the core due to power supply breaker trip during maintenance and was unable to be recovered within the allowed time. All rods were verified to trip normally as part of the controlled shutdown."
The reactor was manually tripped from approx. 20% power. The reactor trip was preplanned.
The NRC Resident Inspector and the county were notified of this event by the licensee. Licensee will also notify the State of this event.