The licensee provided the following information via facsimile:
06/03/05: High Bluff Operating, LLC reported The Rosel Company of Liberal, Kansas lost a logging tool downhole in Clark County, Kansas. The logging cable broke, and the tool dropped to a depth of 5866 feet. The tool was 'fished' from the hole, but the density pad broke off the tool and stayed in the hole. An experienced 'fishing tool expert' recommended that cement the possible source in place.
[High Bluff] proposes: 75' of red dyed cement on top of the pad with a 'whipstock' device preventing reentry of the hole. Set 5740 feet of production casing to prevent deepening. Post at the wellhead a plaque noting the required Information.
06/04/05: [Kansas] replied to [High Bluff] and concurred with his plan.
11/01/05: [High Bluff] sent in his final report. Correct the final depth to 5856'. Modified the plan of action to be 5710 feet of casing and 146 feet of red dyed cement by Allied Cement. The plaque was still awaiting production and placement.
11/11/05: [High Bluff] reported the plaque was unacceptable, and a new plaque was being made.
03/22/06: Received cd-rom of digital pictures taken of well site, time stamped 03/13/2006. Plaque meets general requirements. Event considered closed.
Source: 2 Curie Cs-137, Serial Number CSV-K98 manufactured by Gulf Nuclear
Kansas Report Number: KS050022