ENS 42406
ENS Event | |
|---|---|
06:00 Mar 11, 2006 | |
| Title | Unit Entered a T.S. Required Shutdown After Declaring Both Condenser Offgas Radiation Monitors Inoperable |
| Event Description | Condenser offgas radiation monitor flow was blocked. Both Offgas Radiation Monitors were affected and out of service. We entered T.S. 3.0.1 - When a Limiting Condition for Operation is not met, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> action shall be initiated to place the unit in a condition in which the specification does not apply:
1. Hot Standby within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. 2. Hot Shutdown with following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. 3. Cold Shutdown with subsequent 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. We started to shutdown the Unit at 0100 [hours] on 11 March 2006. Removed blockage from condenser offgas radiation monitors common exhaust and evaluated operability of the condenser offgas radiation monitors. At 0315 [hours] on 11 March 2006, we returned RM-A-5 and RM-A-15 [Condenser Offgas Radiation Monitors] to service and exited T.S. 3.0.1. We stopped the power reduction at 0251 [hours] on 11 March 2006 while performing the evaluation on the condenser offgas radiation monitors. We stopped the power reduction at 73% reactor power. We started power escalation to 100% at 0338 [hours] on 11 March 2006. The blockage was discovered at 2125 hours0.0246 days <br />0.59 hours <br />0.00351 weeks <br />8.085625e-4 months <br /> on 3/10/2006 during rounds by Secondary Plant Operator who noted that the normal 1 SCFM exhaust flow was reading zero flow. During troubleshooting to discover the cause of the blockage, a bluish foreign material was found in the common exhaust piping. An investigation is underway to identify the source of the foreign material. The licensee informed the NRC Resident Inspector. |
| Where | |
|---|---|
| Crane Pennsylvania (NRC Region 1) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown | |
| Time - Person (Reporting Time:+2.58 h0.108 days <br />0.0154 weeks <br />0.00353 months <br />) | |
| Opened: | George Herneisey 08:35 Mar 11, 2006 |
| NRC Officer: | Steve Sandin |
| Last Updated: | Mar 11, 2006 |
| 42406 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 482202012-08-22T06:28:00022 August 2012 06:28:00
[Table view]10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Tech Spec Required Shutdown Due to Reactor Coolant System Pressure Boundary Leak ENS 424062006-03-11T06:00:00011 March 2006 06:00:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Unit Entered a T.S. Required Shutdown After Declaring Both Condenser Offgas Radiation Monitors Inoperable 2012-08-22T06:28:00 | |