At
1130 hours0.0131 days <br />0.314 hours <br />0.00187 weeks <br />4.29965e-4 months <br /> on 01/09, the air cylinder on a gate operating the shutter for a fixed
gauge failed to close. The
gauge, a SenTek device, model not identified, is generally licensed and contains a 1000 mCi
Am-241 source. The device was removed from service and heavy steel plate was positioned to shield the source. Additionally, the affected area was isolated and posted. No unmonitored personnel exposures occurred. A SenTek technician arrived onsite and corrected the malfunctioning shutter as of
0900 hours0.0104 days <br />0.25 hours <br />0.00149 weeks <br />3.4245e-4 months <br /> 01/10/06.
- * * UPDATE 1340 EST ON 1/11/06 FROM STEVE CUSTER TO S. SANDIN * * *
Further investigation determined that the fixed
gauge is a model THAM2 manufactured by
ABB AccuRay. The initial report is required per
10 CFR 30.50(b)(2). AK Steel will be submitting a followup written report within 30 days. Notified R3DO(O'Brien) and
NMSS (Morell).