The following information was provided by the
Texas Department of State Health Services via E-mail (state text in quotes):
Radiography was conducted at both field and fixed locations during the December [2004] monitoring period. The badge of [the radiographer trainee] was the only high badge for the Licensee during the monitoring period. The Radiography Trainer claims that his pocket dosimeter and alarming rate meter showed no unusual activity during the monitoring period. All exposure devices were leak tested December 30, 2004, with no leakage in excess of applicable limits being exceeded - no leakage. The Radiographer Trainer was on two crews during the monitoring period. Both other crew members had normal exposures for the monitoring period. No explanation for a possible source of exposure to the badge was offered by the Licensee or the wearer of the badge. The Licensee was cited for violating the Deep dose annual exposure limits for calendar year 2004.
The trainee was seen by a physician however, the blood work results are not yet available. As corrective action, the licensee has notified all radiographers to carefully monitor their pocket dosimeters and alarming rate meters, and to keep their personal monitoring badges away from sources of radiation.
The four cameras used contained Ir-192 (72.4 Ci, 81.5 Ci, 34.1 Ci, and 39.4 Ci). Total dose received by the radiographer trainee was 11.885 REM DDE for December 2004 and 12.771 REM DDE for the annual monitoring period.
Texas Incident # I-8199.