Geo-Technology Associates, Inc. (GTA) reported the theft of a
Troxler gauge, Model 3411, Serial # 15742. The source strength of this
gauge is 8 milliCi of
Cs-137 and 40 milliCi of
Am-241. A contract employee was last seen with the
gauge when he signed out for the device at GTA's office on the morning of 3/24/05. He was supposed to have gone to a construction job site in Gainesville,
VA, and then return to GTA's office that evening with the
Troxler gauge. It is unknown at this time if he reported to the jobsite or returned to the office.
An employee of GTA came into the office about 07:00 on 03/25/05 and discovered the Troxler gauge missing. Normally a worker returns equipment (Troxler gauge) to the office at the end of each workday. The GTA employee reported the possible theft to the Loudoun County Sheriff in VA.
- UPDATE FROM T. UPSON TO J. KNOKE AT 19:30 ON 03/25/05 ***
An employee of GTA called to report the Troxler gauge was returned to GTA's office sometime between 17:00 and 18:00 on 03/25/05. It was assumed to be the contract employee who originally signed out for the gauge had returned it since it was found inside the locked office of GTA. No visible damage to the device was detected. GTA indicated that early next week a decision would be made on whether or not they will rescind the sheriff's report of a stolen Troxler gauge.
- * * UPDATE FROM T. UPSON TO W. GOTT AT 0950 ON 03/28/05 * * *
The licensee reported that, since the gauge was returned intact and undamaged, they did not plan on pursuing charges against the individual that allegedly used the gauge.
Notified R1DO (J Trapp) and
NMSS (Essig).