ENS Event | |
|---|---|
21:10 Jan 24, 2005 | |
| Title | Unusual Event Due to Unidentified Leakage Greater than 10 Gpm |
| Event Description | The licensee reported that it had indications of unidentified reactor coolant leakage greater than 10 gpm which placed the licensee into an unusual event emergency action level (EAL). Indication of drywell sump level increase and pump out rate gave an approximate leak rate of 30 gpm. The licensee also indicated that drywell pressure was above the normal range. The unusual event declaration was made at 1610 EST.
At 1619 EST, the licensee manually scrammed the reactor. The scram was uncomplicated with all rods fully inserting and all systems functioning as required. Decay heat is being rejected to the main condenser. There has been no ECCS injection actuation and reactor water level is being maintained by feed pumps. The licensee has no significant safety related equipment out of service. The licensee stated that there is no indication of further degradation of the leak rate and the source of the leak is still under investigation The licensee has notified the NRC Resident Inspector along with State, Local, and other government agencies.
At 1640 EST, the licensee upgraded to an ALERT following additional leak rate calculations that indicated the leak rate was approximately 75 - 80 gpm based on drywell sump pump out rate. The licensee's EAL for an alert is RCS leakage greater than 50 gpm. The NRC entered the monitoring mode at 1653 EST. The licensee stated that there has been no increase in drywell radiation levels and that sump water chemistry analysis is in progress. In addition to the normal government agencies notified, the NRC also notified the Canadian Nuclear Safety Commission Duty Officer (R. Chamberlaine).
The licensee has indications that the leakage may not be reactor coolant leakage. Chemistry results show that the sump water radiation levels are at a level less than would be expected for RCS leakage. In addition, a secondary cooling system was found in a lineup configuration that could have masked leakage from the system. The licensee is waiting to get additional chemistry results on the presence of corrosion inhibitors in the sump water to provide additional confirmation that the leakage is not from the RCS.
The licensee confirmed the presence of corrosion inhibitors in the drywell sump. In addition, based on manipulations of the Reactor Building Closed Cooling Water system and the Emergency Equipment Cooling Water system the licensee believes that the leakage is from the Reactor Building Closed Cooling Water system and not RCS leakage. The plant is stable and the licensee is continuing to cool down with pressure now at 180 psi and decreasing.
The licensee terminated its Alert and Unusual Event at 22:28 EST based on sump water chemistry, activity, and Reactor Building Closed Cooling Water System manipulations that indicate the leakage is secondary cooling water and not from the RCS. The NRC secured from the monitoring mode at 22:36 EST. Notified DHS (Belt), FEMA (Caldwell), DOE (Dasilva), EPA (Baumgartner) USDA (Sykes), and HHS( Pyles). The Canadian Nuclear Safety Commission Duty Officer (R. Chamberlaine) was also notified. |
| Where | |
|---|---|
| Fermi Michigan (NRC Region 3) | |
| Reporting | |
| Emergency class: | Alert |
| 10 CFR 50.72(a) (1) (i), Emergency Class Declaration 10 CFR 50.72(b)(2)(iv)(B), RPS Actuation | |
| LER: | 05000341/LER-2005-001 Regarding Manual Reactor Shutdown Due to Containment Cooler Leak |
| Time - Person (Reporting Time:+-4.7 h-0.196 days <br />-0.028 weeks <br />-0.00644 months <br />) | |
| Opened: | Phil Skorbek 16:28 Jan 24, 2005 |
| NRC Officer: | Bill Huffman |
| Last Updated: | Jan 24, 2005 |
| 41354 - NRC Website
Loading map... | |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | Yes, Manual Scram |
| Before | Power Operation (100 %) |
| After | Hot Shutdown (0 %) |
Fermi | |
WEEKMONTHYEARENS 570462024-03-23T04:04:00023 March 2024 04:04:00
[Table view]10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Automatic Reactor Trip ENS 559642022-06-25T03:38:00025 June 2022 03:38:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Automatic Reactor Scram Due to Main Turbine Trip ENS 557322022-02-04T22:00:0004 February 2022 22:00:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Automatic Reactor Scram ENS 533362018-04-14T14:40:00014 April 2018 14:40:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(iv)(A), System Actuation, 10 CFR 50.72(b)(2)(iv)(A), System Actuation - ECCS Discharge Automatic Reactor Scram and Emergency Core Cooling System Injection ENS 513912015-09-14T03:05:00014 September 2015 03:05:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation, 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Manual Scram Due to Loss of Turbine Building Closed Cooling Water ENS 509032015-03-19T11:02:00019 March 2015 11:02:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Automatic Reactor Scram Due to an Oscillation Power Range Monitor Upscale Actuation ENS 499372014-03-20T18:05:00020 March 2014 18:05:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Fermi Declares Alert Due to a Fire in an Emergency Diesel Generator Turbo Charger Lagging ENS 484872012-11-07T14:21:0007 November 2012 14:21:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Manual Reactor Shutdown Due to Hydrogen In-Leakage to Stator Water Cooling System ENS 483092012-09-14T20:03:00014 September 2012 20:03:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(2)(iv)(A), System Actuation - ECCS Discharge Automatic Reactor Scram Due to the Loss of the 120 Kv Switchyard ENS 480472012-06-25T17:30:00025 June 2012 17:30:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Reactor Feed Pump Trip Results in Manual Reactor Scram ENS 463592010-10-24T20:41:00024 October 2010 20:41:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Automatic Reactor Scram Due to a Turbine Trip Resulting from a Low Condenser Vacuum ENS 459792010-06-06T06:38:0006 June 2010 06:38:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Automatic Reactor Scram Due to Partial Loss of Offsite Power ENS 457892010-03-25T20:27:00025 March 2010 20:27:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Automatic Reactor Shutdown Due to Main Turbine Trip ENS 453942009-09-30T15:09:00030 September 2009 15:09:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Manual Reactor Shutdown Due to Hydrogen In-Leakage to Stator Water Cooling System ENS 449422009-03-28T05:46:00028 March 2009 05:46:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Reactor Scram Due to Mode Switch Being Placed in Shutdown Following High Vibration on Main Turbine #1 Bearing ENS 442932008-06-13T05:46:00013 June 2008 05:46:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Due to Partial Loss of Annunciators ENS 439482008-01-31T20:44:00031 January 2008 20:44:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Manual Reactor Scram in Response to Trip of Both Reactor Recirc Pumps ENS 437842007-11-15T08:13:00015 November 2007 08:13:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Reactor Scram - Initiation of Ari Caused by Level 2 Signal ENS 427432006-07-31T17:26:00031 July 2006 17:26:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Co2 Discharge to the Cable Tray Room ENS 427382006-07-29T19:50:00029 July 2006 19:50:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Reactor Scram and Eccs Injection Due to Loss of Feedwater ENS 426432006-06-15T14:53:00015 June 2006 14:53:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Automatic Reactor Scram Due to Turbine Trip ENS 413542005-01-24T21:10:00024 January 2005 21:10:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Due to Unidentified Leakage Greater than 10 Gpm ENS 412432004-12-04T09:17:0004 December 2004 09:17:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Automatic Reactor Scram Due to an Auto Voltage Regulator Trip ENS 410172004-09-04T03:45:0004 September 2004 03:45:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation Rps Actuation ENS 400752003-08-14T20:10:00014 August 2003 20:10:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Plant Entered an Noue Due to the Loss of Off Site Power 2024-03-23T04:04:00 | |