24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Notification to the NRC Operations Center is being made per Operating License No.
NPF-39, Section 2.F to report a potential violation of the requirements contained in Section 2. C of Limerick Unit 1 license.
On September 15, 2004 at 1600 Hrs. it was determined during an investigation of megawatt output differences between the two LGS Units, that LGS Unit 1 secondary plant parameters were identified as being outside of their expected range. This change occurred over several months at the rate of 0.1 %/month for a total potential error of 0.4%. This data indicates that LGS1 could possibly be above the operating license limit of 3458 MWth. Unit 1 power was reduced to 99% power to 3423 MWth as of 1618 to provide margin to licensed thermal power limit.
A written report is required within 30 days in accordance with 10 CFR 50.73.
The licensee has notified the NRC resident inspector.