The incident occurred at Ft Carson, CO in the Direct Support (DS) maintenance Shop on 13 May 2004. It involved a M64A1 mortar sight unit containing 6.69 curies of
tritium gas in sealed source form (NSN 124001-379-7953). The M64 mortar was being turned in by the 10th Special Forces for routine maintenance. It was discovered that a mechanical pin needed to be removed from the M64 in order to fix it. After fixing the pin the device was leak tested. Leak test results showed removable contamination of approximately 2.5 million dpm [disintegrations per minute] (1.12 microcuries). The
RSO took immediate action upon receiving the wipe test result of the device. He double bagged the device and placed it in a secured area. Several area wipes were performed of the shop area and of areas outside the shop area. The shop area showed contamination ranging from 500 dpm to 900 K dpm. The
RSO took action to remove items from the shop that were contaminated. Survey results showed that the
tritium contamination did not spread outside of the machining area. Three persons were bioassayed. Bioassay results were not available at the time of this report.