ENS 40610
ENS Event | |
|---|---|
06:00 Mar 25, 2004 | |
| Title | Part 21 Notification Involving Potential Safety Hazard for Blowers on Op Engines |
| Event Description | Subject:Roots Blower on OP Engines
On March 23, 2004, Fairbanks Morse Engine evaluation determined a potential safety hazard exists for blowers (P/N 16609294) on OP engines. It is possible that the aluminum rotors can slip on the steel shaft and cause rotor-to-rotor or rotor-to-housing contact which could cause blower failure and inability of engine to perform its safety function. The defect was caused by improper cleaning of the shaft prior to casting the rotor onto the shaft. This causes an inadequate bond and allows the aluminum rotor to move axially on the steel shaft. Sample testing of rotors has found this condition to exist to varying degrees on approximately 75% of rotors produced between 1998 and 2003. (4) blowers were shipped to nuclear utilities that may be affected: Utility Site Blower S/N Exelon Limerick (RB813A, RB3871, RB816) Entergy ANO-2 (RB814) To date, no engine failures have been experienced as a result of this problem. However, the potential exists. All slipped rotors have been found during routine maintenance inspections. This condition has been found to manifest itself within a low number of hours of operation. Therefore, the longer the rotors run and maintain proper clearance, the less likely they are to be affected by this condition. The affected utilities will be notified to evaluate inspection results and replace as necessary. |
| Where | |
|---|---|
| Fairbanks Morse Engine Beloit, Wisconsin (NRC Region 3) | |
| Organization: | Fairbanks Morse Engine |
| Reporting | |
| 10 CFR 21.21 | |
| Time - Person (Reporting Time:+11.93 h0.497 days <br />0.071 weeks <br />0.0163 months <br />) | |
| Opened: | Todd Collins (Fax) 17:56 Mar 25, 2004 |
| NRC Officer: | Steve Sandin |
| Last Updated: | Mar 25, 2004 |
| 40610 - NRC Website | |
Fairbanks Morse Engine with 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation | |
WEEKMONTHYEARENS 465232010-11-16T06:00:00016 November 2010 06:00:00
[Table view]10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Part 21 Report for Potential Safety Hazard on Speed Switch Installed on Emergency Diesel Generator (Edg) ENS 432942007-04-09T05:00:0009 April 2007 05:00:00 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Part 21 Notification - Diesel Cam Roller Bushing Failures ENS 406992004-04-21T05:00:00021 April 2004 05:00:00 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Fairbanks Morse Engine Has Determined a Potential Safety Hazard with the Woodward Digital Reference Unit (Dru) ENS 406102004-03-25T06:00:00025 March 2004 06:00:00 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Part 21 Notification Involving Potential Safety Hazard for Blowers on Op Engines ENS 405242004-02-16T06:00:00016 February 2004 06:00:00 10 CFR 21.21, Notification of failure to comply or existence of a defect and its evaluation Part 21.21 Notification of Potential Safety Hazard Associated with Use of Turbocharger 2010-11-16T06:00:00 | |