A
Campbell Pacific Nuclear portable
moisture density gauge Model MC-3, Serial Number MC 39058846 was
stolen from the licensee's storage trailer. The
gauge contains a cesium-americium-beryllium radioactive source (10 millicuries
Cs-137 and 50 millicuries
Am-241/Be). The licensee's trailer containing the
stolen gauge was located at a Home Depot construction site, 1801 Custer Ave, Helena,
MT 59601. Helena City police is investigating this and other thefts that occurred overnight at several trailers located at this same site.
The licensee contacted Region IV (M. Shaffer) and will contact the Montana Department of Health.
- * * UPDATE ON 02/09/05 @ 1819 BY GREG STAFFILENO TO CHAUNCEY GOULD * * *
The licensee was contacted by another company which also uses moisture density gauges to inform them they had in their possession the stolen gauge. The individual that had the device spotted it for sale on the street in Los Angeles CA for $20 and bought it. The devise appeared to be in good shape but has been taken to a local gauge service company where it will be checked out before it is returned to the original licensee.
Notified Reg 4 RDO (Whitten) and
NMSS EO(Reamer)